DC Power Supply
Commands that provide access to DC Power Supply data and functions.
Get Current State
Get the current state of the instrument's channel
Command
- dc - (Object) - The DC power supply object.
- # - (Array<Object>) - An array of command objects to apply to the DC power supply channel.
- command - (String) - The Get Current State command: “getCurrentState”
Response
- gpio - (Object) - The DC power supply object.
- # - (Array<Object>) - An array of command objects applied to the DC power supply channel.
- command - (String) - The Get Current State command: “getCurrentState”
- statusCode - (Integer) - A numeric value representing the device status. See Digilent Instrumentation Protocol Status Codes
- wait - (Integer) - The number of ms to wait before the device is ready to process another command.
- state - (String) - The current state of the channel: “idle” or “running”.
- voltage - (Integer) - The current measured value of the channel in mV.
Example
Command
{
"dc": {
"1": [
{
"command":"getCurrentState"
}
]
}
}
Response
{
"dc": {
"1": [
{
"command": "getCurrentState",
"statusCode": 0,
"wait": 0,
"state": "idle",
"voltage": 3300
}
]
}
}
Get Voltage
Get the output voltage(s) of the specified DC power supply channel(s).
Command
- dc - (Object) - The DC power supply object.
- # - (Array<Object>) - An array of command objects to apply to the DC power supply channel.
- command - (String) - The Get Voltage command: “getVoltage”
Response
- gpio - (Object) - The DC power supply object.
- # - (Array<Object>) - An array of command objects applied to the DC power supply channel.
- command - (String) - The Get Voltage command: “getVoltage”
- statusCode - (Integer) - A numeric value representing the device status. See Digilent Instrumentation Protocol Status Codes
- wait - (Integer) - The number of ms to wait before the device is ready to process another command.
- voltage - (Integer) - The current measured value of the channel in mV.
Example:
Command
{
"dc":{
"1":[
{
"command":"getVoltage"
}
]
}
}
Response
{
"dc":{
"1":[
{
"command":"getVoltage",
"statusCode":0,
"wait":100,
"voltage":3300
}
]
}
}
Set Voltage
Set the output voltage(s) of the specified DC power supply channel(s).
Command
- dc - (Object) - The DC power supply object.
- # - (Array<Object>) - An array of command objects to apply to the DC power supply channel.
- command - (String) - The Set Current State command: “setCurrentState”
- voltage - (Integer) - The desired voltage in mV.
Response
- gpio - (Object) - The DC power supply object.
- # - (Array<Object>) - An array of command objects applied to the DC power supply channel.
- command - (String) - The Set Current State command: “setCurrentState”
- statusCode - (Integer) - A numeric value representing the device status. See Digilent Instrumentation Protocol Status Codes
- wait - (Integer) - The number of ms to wait before the device is ready to process another command.
Example:
Command
{
"dc":{
"1":[
{
"command":"setVoltage",
"voltage":3300
}
]
}
}
Response
{
"dc":{
"1":[
{
"command":"setVoltage",
"statusCode":0,
"wait":500
}
]
}
}