Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:guides:waveforms-waveform-generator [2022/03/16 02:37] – Keith M Kolmostest-and-measurement:guides:waveforms-waveform-generator [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 125: Line 125:
 --> Analog Discovery Pro (ADP5250) # --> Analog Discovery Pro (ADP5250) #
 <WRAP group> <WRAP column half> <WRAP group> <WRAP column half>
-Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the scope probe or minigrabbers to the test signal and test signal ground pins on the front of the ADP5250 to create a loopback circuit.  Check the input probe's attenuation factor, as it will be used later to set up the software.+Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the minigrabbers to the AWG Channel 1  
 +connector on the front of the ADP5250 to create a loopback circuit.  Check the input probe's attenuation factor, as it will be used later to set up the software.
  
 **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.//
Line 260: Line 261:
 {{section>test-and-measurement:analog-discovery-pro-3x50:change-max-sample-rate&noheader}} {{section>test-and-measurement:analog-discovery-pro-3x50:change-max-sample-rate&noheader}}
  
 +==== Note: Analog Discovery Pro (ADP5250) Wavegen Output Filter ====
 +
 +//The Analog Discovery Pro (ADP5250) features a switchable filter on the AWG output. Click the dropdown below to learn how to use this feature.//
 +
 +--> Enable or Disable the ADP5250's AWG Filter #
 +<WRAP group> <WRAP column half>
 +This filter can be enabled or disabled through the use of the dropdown on the right side of the control toolbar. It can be set to Auto, On, or Off.
 +</WRAP> <WRAP column half>
 +{{:test-and-measurement:guides:filter.jpg?400 |}}
 +</WRAP> </WRAP>
 +<--
 +
 +----
 ==== Note: Using Multiple Instruments ==== ==== Note: Using Multiple Instruments ====
 The //Waveform Generator// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit and view the response with the //Oscilloscope//, all at the same time. More information on how instruments can be operated together can be found in the [[test-and-measurement:guides:waveforms-cross-triggers]] guide. The //Waveform Generator// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit and view the response with the //Oscilloscope//, all at the same time. More information on how instruments can be operated together can be found in the [[test-and-measurement:guides:waveforms-cross-triggers]] guide.
Line 332: Line 346:
 </WRAP> <WRAP column half> </WRAP> <WRAP column half>
 {{:learn:instrumentation:tutorials:analog-discovery-studio-waveform-generator:waveforms-wavegen-edit.png?600|}} {{:learn:instrumentation:tutorials:analog-discovery-studio-waveform-generator:waveforms-wavegen-edit.png?600|}}
-</WRAP> </WRAP> 
- 
-<WRAP group> <WRAP column half> 
-**On the Analog Discovery Pro 5250 only** 
-The Wavegen instrument has an additional control setting when using an Analog Discovery Pro 5250.  There is a **Filter** setting to the right of the Idle setting.  The filter can be set to Auto, On, or Off.  If you click on the gear icon to the right of filter, you can adjust the amplification for the filter from 100X, 10X, 1 X, 0.1X, or 0.01X.   
-</WRAP> <WRAP column half> 
-{{:test-and-measurement:guides:amplification.jpg?400 |}} 
-{{:test-and-measurement:guides:filter.jpg?400 |}} 
 </WRAP> </WRAP> </WRAP> </WRAP>