Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| test-and-measurement:guides:waveforms-waveform-generator [2022/03/16 02:35] – Keith M Kolmos | test-and-measurement:guides:waveforms-waveform-generator [2022/10/04 11:38] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 125: | Line 125: | ||
| --> Analog Discovery Pro (ADP5250) # | --> Analog Discovery Pro (ADP5250) # | ||
| <WRAP group> <WRAP column half> | <WRAP group> <WRAP column half> | ||
| - | Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the scope probe or minigrabbers to the test signal and test signal ground pins on the front of the ADP5250 to create a loopback circuit. | + | Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the minigrabbers to the AWG Channel 1 |
| + | connector | ||
| **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// | **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// | ||
| Line 260: | Line 261: | ||
| {{section> | {{section> | ||
| + | ==== Note: Analog Discovery Pro (ADP5250) Wavegen Output Filter ==== | ||
| + | |||
| + | //The Analog Discovery Pro (ADP5250) features a switchable filter on the AWG output. Click the dropdown below to learn how to use this feature.// | ||
| + | |||
| + | --> Enable or Disable the ADP5250' | ||
| + | <WRAP group> <WRAP column half> | ||
| + | This filter can be enabled or disabled through the use of the dropdown on the right side of the control toolbar. It can be set to Auto, On, or Off. | ||
| + | </ | ||
| + | {{: | ||
| + | </ | ||
| + | <-- | ||
| + | |||
| + | ---- | ||
| ==== Note: Using Multiple Instruments ==== | ==== Note: Using Multiple Instruments ==== | ||
| The //Waveform Generator// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit and view the response with the // | The //Waveform Generator// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit and view the response with the // | ||
| Line 332: | Line 346: | ||
| </ | </ | ||
| {{: | {{: | ||
| - | </ | ||
| - | |||
| - | <WRAP group> | ||
| - | <WRAP column half> | ||
| - | |||
| - | <WRAP group> <WRAP column half> | ||
| - | **On the Analog Discovery Pro 5250 only** | ||
| - | The Wavegen instrument has an additional control setting when using an Analog Discovery Pro 5250. There is a **Filter** setting to the right of the Idle setting. | ||
| - | </ | ||
| - | {{: | ||
| - | {{: | ||
| </ | </ | ||