Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| test-and-measurement:guides:waveforms-waveform-generator [2022/03/04 02:21] – [Prerequisites] Keith M Kolmos | test-and-measurement:guides:waveforms-waveform-generator [2022/10/04 11:38] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 10: | Line 10: | ||
| ===== Prerequisites ===== | ===== Prerequisites ===== | ||
| * A Digilent Test & Measurement Device with Analog Input and Output Channels: | * A Digilent Test & Measurement Device with Analog Input and Output Channels: | ||
| - | * [[test-and-measurement: | + | * [[test-and-measurement: |
| * [[test-and-measurement: | * [[test-and-measurement: | ||
| * [[test-and-measurement: | * [[test-and-measurement: | ||
| Line 120: | Line 120: | ||
| </ | </ | ||
| {{reference: | {{reference: | ||
| + | </ | ||
| + | <-- | ||
| + | |||
| + | --> Analog Discovery Pro (ADP5250) # | ||
| + | <WRAP group> <WRAP column half> | ||
| + | Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the minigrabbers to the AWG Channel 1 | ||
| + | connector on the front of the ADP5250 to create a loopback circuit. | ||
| + | |||
| + | **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// | ||
| + | |||
| + | **Note:** //When using BNC Probes, make sure to take note of the probes' | ||
| + | </ | ||
| + | {{: | ||
| </ | </ | ||
| <-- | <-- | ||
| Line 248: | Line 261: | ||
| {{section> | {{section> | ||
| + | ==== Note: Analog Discovery Pro (ADP5250) Wavegen Output Filter ==== | ||
| + | |||
| + | //The Analog Discovery Pro (ADP5250) features a switchable filter on the AWG output. Click the dropdown below to learn how to use this feature.// | ||
| + | |||
| + | --> Enable or Disable the ADP5250' | ||
| + | <WRAP group> <WRAP column half> | ||
| + | This filter can be enabled or disabled through the use of the dropdown on the right side of the control toolbar. It can be set to Auto, On, or Off. | ||
| + | </ | ||
| + | {{: | ||
| + | </ | ||
| + | <-- | ||
| + | |||
| + | ---- | ||
| ==== Note: Using Multiple Instruments ==== | ==== Note: Using Multiple Instruments ==== | ||
| The //Waveform Generator// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit and view the response with the // | The //Waveform Generator// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit and view the response with the // | ||
| Line 324: | Line 350: | ||
| <WRAP group> | <WRAP group> | ||
| <WRAP column half> | <WRAP column half> | ||
| + | |||
| === 3.2 The Preview Plot === | === 3.2 The Preview Plot === | ||

