Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| test-and-measurement:guides:waveforms-voltmeter [2022/09/12 15:41] – changed forum.digilentinc.com to forum.digilent.com jeff.greenberg_ni.com | test-and-measurement:guides:waveforms-voltmeter [2022/10/04 11:38] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | ====== Using the Voltmeter ====== | ||
| + | |||
| + | ~~TechArticle~~ | ||
| + | |||
| + | {{reference: | ||
| + | |||
| + | ===== Introduction ===== | ||
| + | Voltmeters are used to take quick and easy measurements of AC and DC analog signals. This guide explains the use of the // | ||
| + | ---- | ||
| + | ===== Prerequisites ===== | ||
| + | * A Digilent Test & Measurement Device with Analog Input Channels: | ||
| + | * [[test-and-measurement: | ||
| + | * [[test-and-measurement: | ||
| + | * [[test-and-measurement: | ||
| + | * [[test-and-measurement: | ||
| + | * A Computer with WaveForms Software Installed | ||
| + | |||
| + | ---- | ||
| + | ===== Guide ===== | ||
| + | ==== 1. Opening the Voltmeter ==== | ||
| + | |||
| + | <WRAP group> | ||
| + | <WRAP column half> | ||
| + | === 1.1 === | ||
| + | Plug in the Test & Measurement Device, then start WaveForms and make sure the device is connected. | ||
| + | |||
| + | If no device is connected to the host computer when WaveForms launches, the **Device Manager** will be launched. Make sure that the device is plugged in and turned on, at which point it will appear in the Device Manager' | ||
| + | |||
| + | **Note:** //" | ||
| + | |||
| + | **Note:** //The Device Manager can be opened by clicking on the " | ||
| + | </ | ||
| + | <WRAP column half> | ||
| + | {{ reference: | ||
| + | </ | ||
| + | </ | ||
| + | ---- | ||
| + | <WRAP group>< | ||
| + | === 1.2 === | ||
| + | Once the Welcome page loads, in the instrument panel at the left side of the window, click on the **Voltmeter** button to open the // | ||
| + | </ | ||
| + | {{ : | ||
| + | </ | ||
| + | ---- | ||
| + | |||
| + | <WRAP group> | ||
| + | <WRAP column half> | ||
| + | |||
| + | === 1.3 === | ||
| + | Once the // | ||
| + | |||
| + | </ | ||
| + | <WRAP column half> | ||
| + | |||
| + | {{: | ||
| + | |||
| + | </ | ||
| + | </ | ||
| + | |||
| + | ----- | ||
| + | |||
| + | ==== 2. Using the Voltmeter ==== | ||
| + | |||
| + | //This section walks through setting up the // | ||
| + | |||
| + | === 2.1 Hardware Setup === | ||
| + | The // | ||
| + | |||
| + | If using the analog output channels, open the Wavegen instrument, and run it with default settings (note that a 1 V sine wave corresponds to an RMS Voltage of 700 mV). If using a power supply, open the Supplies instrument and enable it. | ||
| + | |||
| + | **Note:** //Negative pins and grounds should be connected as required by your device. If using an Analog Discovery Studio or Analog Discovery 2, make sure to connect the analog input channel negative pins, labeled “1-” (orange wire with white stripes) and “2-” (blue wire with white stripes) to the ground of the connected circuit. If using an Analog Discovery Pro (ADP3450/ | ||
| + | |||
| + | The analog input channels can be used with BNC Cables if supported by your device. For more information, | ||
| + | |||
| + | ---- | ||
| + | === 2.2 Run the Voltmeter === | ||
| + | <WRAP group>< | ||
| + | In the // | ||
| + | |||
| + | </ | ||
| + | <WRAP column half> | ||
| + | |||
| + | {{: | ||
| + | |||
| + | </ | ||
| + | </ | ||
| + | |||
| + | ----- | ||
| + | ==== Note: Using Multiple Instruments ==== | ||
| + | The // | ||
| + | |||
| + | It should be noted that the analog input channels cannot be shared by multiple instruments. When the Voltmeter is enabled, any other instruments using the analog input channels are disabled. Other instruments that use the analog input channels include the // | ||
| + | ---- | ||
| + | ==== 3. Voltmeter User Interface Overview ==== | ||
| + | |||
| + | <WRAP group> | ||
| + | <WRAP column half> | ||
| + | |||
| + | The // | ||
| + | |||
| + | The // | ||
| + | |||
| + | The **File** menu, in the menu bar at the top of the Voltmeter instrument, allows the user to save and load Voltmeter instrument configurations and export an image of the Voltmeter. | ||
| + | |||
| + | The **Control** menu exposes the same functionality as the Single, Run and Stop buttons, and lists hotkeys for the buttons. | ||
| + | |||
| + | The **Window** menu provides a fast way to switch to other tabs open in WaveForms. | ||
| + | |||
| + | </ | ||
| + | <WRAP column half> | ||
| + | |||
| + | {{: | ||
| + | |||
| + | </ | ||
| + | </ | ||
| + | |||
| + | ==== Next Steps ==== | ||
| + | |||
| + | For more guides on how to use the Digilent Test & Measurement Device, return to the device' | ||
| + | |||
| + | If voltage values seen in the // | ||
| + | |||
| + | For more information on WaveForms visit the [[software: | ||
| + | |||
| + | For technical support, please visit the [[https:// | ||

