Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:guides:waveforms-voltmeter [2021/05/14 23:05] – ↷ Page moved from reference:test-and-measurement:guides:waveforms-voltmeter to test-and-measurement:guides:waveforms-voltmeter Arthur Browntest-and-measurement:guides:waveforms-voltmeter [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 10: Line 10:
 ===== Prerequisites ===== ===== Prerequisites =====
   * A Digilent Test & Measurement Device with Analog Input Channels:   * A Digilent Test & Measurement Device with Analog Input Channels:
-    * [[reference:test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]] +    * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]] 
-    * [[reference:test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]] +    * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]] 
-    * [[reference:test-and-measurement:analog-discovery-2:start|Analog Discovery 2]] +    * [[test-and-measurement:analog-discovery-2:start|Analog Discovery 2]] 
-    * [[reference:test-and-measurement:analog-discovery:start|Analog Discovery (Legacy)]]+    * [[test-and-measurement:analog-discovery:start|Analog Discovery (Legacy)]]
   * A Computer with WaveForms Software Installed   * A Computer with WaveForms Software Installed
  
Line 71: Line 71:
 **Note:** //Negative pins and grounds should be connected as required by your device. If using an Analog Discovery Studio or Analog Discovery 2, make sure to connect the analog input channel negative pins, labeled “1-” (orange wire with white stripes) and “2-” (blue wire with white stripes) to the ground of the connected circuit. If using an Analog Discovery Pro (ADP3450/ADP3250), connect the BNC cable ground clips to the ground of the circuit you are measuring.// **Note:** //Negative pins and grounds should be connected as required by your device. If using an Analog Discovery Studio or Analog Discovery 2, make sure to connect the analog input channel negative pins, labeled “1-” (orange wire with white stripes) and “2-” (blue wire with white stripes) to the ground of the connected circuit. If using an Analog Discovery Pro (ADP3450/ADP3250), connect the BNC cable ground clips to the ground of the circuit you are measuring.//
  
-The analog input channels can be used with BNC Cables if supported by your device. For more information, see the [[reference:test-and-measurement:guides:waveforms-oscilloscope]] guide. If 10x attenuation is used with the cables, this value must be entered into the appropriate channel's attenuation field, found in the gear ({{:learn:instrumentation:tutorials:waveforms-buttons:waveforms-gear.png?nolink}}) dropdown, next to the Voltmeter's Start/Stop button.+The analog input channels can be used with BNC Cables if supported by your device. For more information, see the [[test-and-measurement:guides:waveforms-oscilloscope]] guide. If 10x attenuation is used with the cables, this value must be entered into the appropriate channel's attenuation field, found in the gear ({{:learn:instrumentation:tutorials:waveforms-buttons:waveforms-gear.png?nolink}}) dropdown, next to the Voltmeter's Start/Stop button.
  
 ---- ----
Line 88: Line 88:
 ----- -----
 ==== Note: Using Multiple Instruments ==== ==== Note: Using Multiple Instruments ====
-The //Voltmeter// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit, and view the response with the //Voltmeter//, all at the same time. More information on how instruments can be operated together can be found in the [[reference:test-and-measurement:guides:waveforms-cross-triggers]] guide.+The //Voltmeter// instrument can be used with other WaveForms instruments. Using multiple instruments at the same time is helpful in a wide variety of situations. One example would be to use the //Waveform Generator// to stimulate a circuit under test, the //Power Supplies// to provide power to the circuit, and view the response with the //Voltmeter//, all at the same time. More information on how instruments can be operated together can be found in the [[test-and-measurement:guides:waveforms-cross-triggers]] guide.
  
 It should be noted that the analog input channels cannot be shared by multiple instruments. When the Voltmeter is enabled, any other instruments using the analog input channels are disabled. Other instruments that use the analog input channels include the //Oscilloscope//, //Data Logger//, //Spectrum Analyzer//, //Network Analyzer//, and //Impedance Analyzer//. It should be noted that the analog input channels cannot be shared by multiple instruments. When the Voltmeter is enabled, any other instruments using the analog input channels are disabled. Other instruments that use the analog input channels include the //Oscilloscope//, //Data Logger//, //Spectrum Analyzer//, //Network Analyzer//, and //Impedance Analyzer//.
Line 117: Line 117:
 ==== Next Steps ==== ==== Next Steps ====
  
-For more guides on how to use the Digilent Test & Measurement Device, return to the device's Resource Center, linked from the [[reference:test-and-measurement:start]] page of this wiki.+For more guides on how to use the Digilent Test & Measurement Device, return to the device's Resource Center, linked from the [[test-and-measurement:start]] page of this wiki.
  
-If voltage values seen in the //Voltmeter// are significantly different from expected, please calibrate the device by following the [[reference:test-and-measurement:guides:waveforms-calibration|Calibration Guide]].+If voltage values seen in the //Voltmeter// are significantly different from expected, please calibrate the device by following the [[test-and-measurement:guides:waveforms-calibration|Calibration Guide]].
  
-For more information on WaveForms visit the [[reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. +For more information on WaveForms visit the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. 
  
-For technical support, please visit the [[https://forum.digilentinc.com/forum/8-scopes-instruments/|Scopes and Instruments]] section of the Digilent Forums.+For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums.