Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:guides:waveforms-spectrum-analyzer [2021/05/14 23:05] – ↷ Page moved from reference:test-and-measurement:guides:waveforms-spectrum-analyzer to test-and-measurement:guides:waveforms-spectrum-analyzer Arthur Browntest-and-measurement:guides:waveforms-spectrum-analyzer [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 27: Line 27:
 ===== Prerequisites ===== ===== Prerequisites =====
   * A Digilent Test & Measurement Device with Analog Input and Output Channels:   * A Digilent Test & Measurement Device with Analog Input and Output Channels:
 +    * [[test-and-measurement:analog-discovery-pro-5250:start|Analog Discovery Pro (ADP5250)]]
     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]
     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]
Line 105: Line 106:
 From the //Spectrum Analyzer// instrument, opened in [[#section12|Section 1.2]], return to WaveForms' Welcome page by clicking on its tab at the top of the screen. In the Welcome tab, open the //Wavegen// instrument (noted by the red arrow in the image at right). Click the Run button ({{:learn:instrumentation:tutorials:waveforms-buttons:waveforms-run.png?nolink}}) in the control bar near the top of the window (red box in image at right) to begin outputting a signal. With default settings, a 1V (2V<sub>PP</sub>), 1kHz sine wave is applied to the Wavegen Channel 1 output pin. Change the **Frequency** to 500kHz by selecting the value from the drop-down menu or by typing into the text field, including the SI prefix.  From the //Spectrum Analyzer// instrument, opened in [[#section12|Section 1.2]], return to WaveForms' Welcome page by clicking on its tab at the top of the screen. In the Welcome tab, open the //Wavegen// instrument (noted by the red arrow in the image at right). Click the Run button ({{:learn:instrumentation:tutorials:waveforms-buttons:waveforms-run.png?nolink}}) in the control bar near the top of the window (red box in image at right) to begin outputting a signal. With default settings, a 1V (2V<sub>PP</sub>), 1kHz sine wave is applied to the Wavegen Channel 1 output pin. Change the **Frequency** to 500kHz by selecting the value from the drop-down menu or by typing into the text field, including the SI prefix. 
  
-For more detail on how to use the //Wavegen// instrument, please see the [[reference:test-and-measurement:guides:waveforms-waveform-generator|Using the Waveform Generator]] guide.+For more detail on how to use the //Wavegen// instrument, please see the [[test-and-measurement:guides:waveforms-waveform-generator|Using the Waveform Generator]] guide.
  
 Return to the //Spectrum Analyzer// instrument by clicking on its tab in the bar at the top of the screen. Return to the //Spectrum Analyzer// instrument by clicking on its tab in the bar at the top of the screen.
Line 221: Line 222:
 The Gear icon in the top right of the Trace window can be used further configure the Trace, with color, name, label, and windowing technique options. To remove a Trace, click the red X to the right of the Gear icon. The Gear icon in the top right of the Trace window can be used further configure the Trace, with color, name, label, and windowing technique options. To remove a Trace, click the red X to the right of the Gear icon.
  
-For more information on Trace configuration, please see the WaveForms reference manual, available through the Help menu in WaveForms, in the menu bar at the top of the screen. An online version of the [[:reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]] is also available.+For more information on Trace configuration, please see the WaveForms reference manual, available through the Help menu in WaveForms, in the menu bar at the top of the screen. An online version of the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]] is also available.
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
Line 308: Line 309:
 */ */
  
-For more guides on how to use the Digilent Test & Measurement Device, return to the device's Resource Center, linked from the [[reference:test-and-measurement:start]] page of this wiki.+For more guides on how to use the Digilent Test & Measurement Device, return to the device's Resource Center, linked from the [[test-and-measurement:start]] page of this wiki.
  
-For more information on WaveForms visit the [[reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. +For more information on WaveForms visit the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. 
  
-For technical support, please visit the [[https://forum.digilentinc.com/forum/8-scopes-instruments/|Scopes and Instruments]] section of the Digilent Forums.+For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums.