Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| test-and-measurement:guides:waveforms-oscilloscope [2022/03/04 02:00] – Keith M Kolmos | test-and-measurement:guides:waveforms-oscilloscope [2022/10/04 11:38] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 10: | Line 10: | ||
| ===== Prerequisites ===== | ===== Prerequisites ===== | ||
| * A Digilent Test and Measurement Device with Analog Input and Output Channels: | * A Digilent Test and Measurement Device with Analog Input and Output Channels: | ||
| + | * [[test-and-measurement: | ||
| * [[test-and-measurement: | * [[test-and-measurement: | ||
| * [[test-and-measurement: | * [[test-and-measurement: | ||
| Line 113: | Line 114: | ||
| </ | </ | ||
| <-- | <-- | ||
| - | + | --> Analog Discovery Pro (ADP3450/ | |
| - | --> Analog Discovery Pro (ADP5250) # | + | |
| <WRAP group> <WRAP column half> | <WRAP group> <WRAP column half> | ||
| - | Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the scope probe or minigrabbers to the test signal and test signal ground pins on the front of the ADP5250 | + | Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and a set of BNC minigrabbers to its Wavegen Out Channel 1 connector. Connect these together, as pictured, |
| **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// | **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// | ||
| Line 122: | Line 122: | ||
| **Note:** //When using BNC Probes, make sure to take note of the probes' | **Note:** //When using BNC Probes, make sure to take note of the probes' | ||
| </ | </ | ||
| - | {{: | + | {{reference: |
| </ | </ | ||
| <-- | <-- | ||
| - | --> Analog Discovery Pro (ADP3450/ | + | |
| + | --> Analog Discovery Pro (ADP5250) # | ||
| <WRAP group> <WRAP column half> | <WRAP group> <WRAP column half> | ||
| - | Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and a set of BNC minigrabbers to its Wavegen Out Channel 1 connector. Connect these together, as pictured, | + | Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the BNC minigrabbers to the AWG Channel 1 connector |
| **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// | **Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.// | ||
| Line 133: | Line 134: | ||
| **Note:** //When using BNC Probes, make sure to take note of the probes' | **Note:** //When using BNC Probes, make sure to take note of the probes' | ||
| </ | </ | ||
| - | {{reference: | + | {{: |
| </ | </ | ||
| <-- | <-- | ||
| - | |||
| ---- | ---- | ||