test-and-measurement:guides:waveforms-oscilloscope [2021/05/14 23:05] – ↷ Page moved from reference:test-and-measurement:guides:waveforms-oscilloscope to test-and-measurement:guides:waveforms-oscilloscope Arthur Browntest-and-measurement:guides:waveforms-oscilloscope [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 10: Line 10:
 ===== Prerequisites ===== ===== Prerequisites =====
   * A Digilent Test and Measurement Device with Analog Input and Output Channels:   * A Digilent Test and Measurement Device with Analog Input and Output Channels:
-    * [[reference:test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]] +    * [[test-and-measurement:analog-discovery-pro-5250:start|Analog Discovery Pro (ADP5250)]]  
-    * [[reference:test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]] +    * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]] 
-    * [[reference:test-and-measurement:analog-discovery-2:start|Analog Discovery 2]] +    * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]] 
-    * [[reference:test-and-measurement:analog-discovery:start|Analog Discovery (Legacy)]] +    * [[test-and-measurement:analog-discovery-2:start|Analog Discovery 2]] 
-  * A Computer with [[reference:software:waveforms:waveforms-3:start|WaveForms]] Software Installed+    * [[test-and-measurement:analog-discovery:start|Analog Discovery (Legacy)]] 
 +  * A Computer with [[software:waveforms:waveforms-3:start|WaveForms]] Software Installed
  
 ---- ----
Line 113: Line 114:
 </WRAP> </WRAP> </WRAP> </WRAP>
 <-- <--
- 
 --> Analog Discovery Pro (ADP3450/ADP3250) # --> Analog Discovery Pro (ADP3450/ADP3250) #
 <WRAP group> <WRAP column half> <WRAP group> <WRAP column half>
Line 125: Line 125:
 </WRAP> </WRAP> </WRAP> </WRAP>
 <-- <--
 +
 +--> Analog Discovery Pro (ADP5250) #
 +<WRAP group> <WRAP column half>
 +Connect a BNC oscilloscope probe to the Analog Discovery Pro's Oscilloscope Channel 1 connector and the BNC minigrabbers to the AWG Channel 1 connector on the front of the ADP5250 to create a loopback circuit.  Check the input probe's attenuation factor, as it will be used later to set up the software.
 +
 +**Note:** //While BNC Probes are single-ended (as is the Waveform Generator hardware), a connected circuit must still share a common ground with the device. No more than one ground should be connected, in order to avoid the creation of ground loops, which may damage your device.//
 +
 +**Note:** //When using BNC Probes, make sure to take note of the probes' bandwidth. When probes are used with an oscilloscope, the achievable bandwidth is limited by both the probes and by the scope. For example, using 1 MHz probes will limit the bandwidth to 1 MHz, even if that is below the Test and Measurement device's specified maximum.//
 +</WRAP> <WRAP column half>
 +{{:test-and-measurement:guides:updated5250scope.jpg?600 |}}
 +</WRAP> </WRAP>
 +<--
 +
 ---- ----
 <WRAP group> <WRAP column half> <WRAP group> <WRAP column half>
Line 148: Line 161:
 <-- <--
 ---- ----
-{{section>reference:test-and-measurement:analog-discovery-pro-3x50:change-max-sample-rate&noheader}}+{{section>test-and-measurement:analog-discovery-pro-3x50:change-max-sample-rate&noheader}}
  
 //The Analog Discovery Pro (ADP3450/ADP3250) features an additional 20 MHz bandwidth filter that can optionally be enabled for each oscilloscope channel. Click the dropdown below to learn how to enable this filter.// //The Analog Discovery Pro (ADP3450/ADP3250) features an additional 20 MHz bandwidth filter that can optionally be enabled for each oscilloscope channel. Click the dropdown below to learn how to enable this filter.//
Line 233: Line 246:
 Immediately next to the Single button are a set of options that can be used to configure oscilloscope triggers. When taking repeated measurements, the plot pane stays centered on these trigger events. As seen above, when the Single button is pressed, a set of data centered on the next trigger event is captured and plotted. Immediately next to the Single button are a set of options that can be used to configure oscilloscope triggers. When taking repeated measurements, the plot pane stays centered on these trigger events. As seen above, when the Single button is pressed, a set of data centered on the next trigger event is captured and plotted.
  
-The **Mode** drop-down allows the user to select what will happen when the Run button is pressed. For descriptions of the available settings, please see the WaveForms reference manual, available through the Help menu in WaveForms, in the menu bar at the top of the screen. The reference manual is also hosted on the Digilent Wiki at this link: [[:reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]].+The **Mode** drop-down allows the user to select what will happen when the Run button is pressed. For descriptions of the available settings, please see the WaveForms reference manual, available through the Help menu in WaveForms, in the menu bar at the top of the screen. The reference manual is also hosted on the Digilent Wiki at this link: [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]].
  
 The **Source** drop-down allows the user to trigger the oscilloscope based on events in other instruments. For more information, please see [[waveforms-cross-triggers]]. The **Source** drop-down allows the user to trigger the oscilloscope based on events in other instruments. For more information, please see [[waveforms-cross-triggers]].
Line 402: Line 415:
 ==== Next Steps ==== ==== Next Steps ====
  
-For more guides on how to use the Digilent Test and Measurement device, return to the device's Resource Center, linked from the [[reference:test-and-measurement:start]] page of this wiki.+For more guides on how to use the Digilent Test and Measurement device, return to the device's Resource Center, linked from the [[test-and-measurement:start]] page of this wiki.
  
 If voltage values seen in the //Scope// are significantly different from expected, please calibrate the device by following the [[waveforms-calibration|Calibration Guide]]. If voltage values seen in the //Scope// are significantly different from expected, please calibrate the device by following the [[waveforms-calibration|Calibration Guide]].
  
-For more information on WaveForms, visit the [[reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. +For more information on WaveForms, visit the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. 
  
 For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums. For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums.