Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:guides:waveforms-network-analyzer [2021/05/14 23:05] – ↷ Page moved from reference:test-and-measurement:guides:waveforms-network-analyzer to test-and-measurement:guides:waveforms-network-analyzer Arthur Browntest-and-measurement:guides:waveforms-network-analyzer [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 10: Line 10:
 ===== Prerequisites ===== ===== Prerequisites =====
   * A Digilent Test & Measurement Device with Analog Input and Output Channels:   * A Digilent Test & Measurement Device with Analog Input and Output Channels:
 +    * [[test-and-measurement:analog-discovery-pro-5250:start|Analog Discovery Pro (ADP5250)]]
     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]
     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]
Line 81: Line 82:
 <WRAP column half> <WRAP column half>
 ===2.2 Run the Network Analyzer=== ===2.2 Run the Network Analyzer===
-By default, the //Network Analyzer// uses the Test & Measurement Device's Wavegen channel 1 as the source signal and does not need any further configuration from the wavegen instrument window. From the control bar, click Run to continuously sweep the circuit network with an input signal of varying frequency - by default, the frequency sweep ranges from 1kHz to 1MHz.+By default, the //Network Analyzer// uses the Test & Measurement Device's Wavegen channel 1 as the source signal and does not need any further configuration from the wavegen instrument window. From the control bar, click Run to continuously sweep the circuit network with an input signal of varying frequency - by default, the frequency sweep ranges from 1 kHz to 1 MHz.
  
 While sweeping, the Run button ({{learn:instrumentation:tutorials:waveforms-buttons:waveforms-run.png?nolink}}) changes to Stop ({{learn:instrumentation:tutorials:waveforms-buttons:waveforms-stop.png?nolink}}). Click Stop to stop outputting analog voltages, and to stop capturing data on the analog input pins. Click Single ({{learn:instrumentation:tutorials:waveforms-buttons:waveforms-single.png?nolink}}) to sweep the circuit network only once. While sweeping, the Run button ({{learn:instrumentation:tutorials:waveforms-buttons:waveforms-run.png?nolink}}) changes to Stop ({{learn:instrumentation:tutorials:waveforms-buttons:waveforms-stop.png?nolink}}). Click Stop to stop outputting analog voltages, and to stop capturing data on the analog input pins. Click Single ({{learn:instrumentation:tutorials:waveforms-buttons:waveforms-single.png?nolink}}) to sweep the circuit network only once.
  
 With the Wavegen connected to the scope channel 2 input, the plot panes should show channel 2 (blue trace) as a flat 0db magnitude plot, channel 1 (yellow traces) magnitude plot decreasing from 0dB to -40dB (this is the magnitude of the filter's frequency response). With the Wavegen connected to the scope channel 2 input, the plot panes should show channel 2 (blue trace) as a flat 0db magnitude plot, channel 1 (yellow traces) magnitude plot decreasing from 0dB to -40dB (this is the magnitude of the filter's frequency response).
-To view channel 1 phase plot decreasing from 0 degrees to -90 degrees (this is the phase of the filter's frequency response), set the phase reference to channel 2.+To view the channel 1 phase plot decreasing from 0 degrees to -90 degrees (this is the phase of the filter's frequency response), set the phase reference to channel 2.
  
 When using a device with more than two channels, these channels are also present in the plot panes and have their own configuration options. When using a device with more than two channels, these channels are also present in the plot panes and have their own configuration options.
Line 107: Line 108:
 By default, the top pane displays the magnitude response of the circuit network in decibels (from +10dB to -90dB) and the bottom pane displays the phase response of the circuit network in degrees (from +180° to -180°). These respective values are on the left side vertical axis and are adjusted using the configuration panel.  By default, the top pane displays the magnitude response of the circuit network in decibels (from +10dB to -90dB) and the bottom pane displays the phase response of the circuit network in degrees (from +180° to -180°). These respective values are on the left side vertical axis and are adjusted using the configuration panel. 
  
-The bottom axis is shared by both plots and by default displays every frequency in the sweep range (1kHz to 1MHz). The range can be adjusted using the Control Bar. Alternately, the range can be changed by hovering a mouse over an axis or plot pane and scrolling the mouse wheel.+The bottom axis is shared by both plots and by default displays every frequency in the sweep range (1 kHz to 1 MHz). The range can be adjusted using the Control Bar. Alternately, the range can be changed by hovering a mouse over an axis or plot pane and scrolling the mouse wheel.
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
Line 135: Line 136:
 //This section walks through the wide variety of controls and features present in the //Network Analyzer// instrument.// //This section walks through the wide variety of controls and features present in the //Network Analyzer// instrument.//
  
-{{reference:test-and-measurement:guides:controlbar.png?600|}}+{{ reference:test-and-measurement:guides:controlbar.png |}}
  
 <WRAP group> <WRAP group>
 <WRAP column half> <WRAP column half>
 ===3.1 Control Bar=== ===3.1 Control Bar===
-The Control Bar can be found above the plot pane. The control bar contains the Single and Run acquisition buttons, as well as several settings that control the frequency sweep used to probe the circuit under test, accessible via either drop-down menus or text field.+The Control Bar can be found above the plot pane. The control bar contains the Single and Run acquisition buttons, as well as several settings that control the frequency sweep used to probe the circuit under test, accessible via either drop-down menus or text fields.
  
-  * **Start:** Allows you to set the START frequency for the sweep.  The range is 10 uHz to 25 MHz. +Additionally, a diagram of the suggested setup surrounding your circuit or device under test can be seen on the right side of the control bar. 
-  * **Stop:** Allows you to set the STOP frequency for the sweep.  The range is 10 uHz to 25 Mhz. + 
 +  * **Start:** Allows you to set the frequency that the sweep starts at.  The range is 10 uHz to 25 MHz. 
 +  * **Stop:** Allows you to set the frequency that the sweep stops at.  The range is 10 uHz to 25 MHz. 
   * **Steps:** Controls how many samples are captured during a sweep. Defines the change in frequency between each sample. (Only applicable for Linear scale)   * **Steps:** Controls how many samples are captured during a sweep. Defines the change in frequency between each sample. (Only applicable for Linear scale)
-  * **/Decade:** "Samples per Decade", controls how many samples are captured during a sweep. A "decade" represents a factor of ten between two frequencies. For example, if a sweep starts at 10kHz, and /Decade is set to 20, 20 samples will be captured +  * **/Decade:** "Samples per Decade", controls how many samples are captured during a sweep. A "decade" represents a factor of ten between two frequencies. For example, if a sweep starts at 10 kHz, and /Decade is set to 20, 20 samples will be captured 
   * **Source:** Set the source of the capture.  Options are external, Wavegen C1, or Wavegen C2.   * **Source:** Set the source of the capture.  Options are external, Wavegen C1, or Wavegen C2.
   * **Mode:** Drop-down menu to enable/disable amplitude sweep (Constant – only frequency sweep mode, or Table – frequency and amplitude sweep) or to define a custom excitation with JavaScript syntax   * **Mode:** Drop-down menu to enable/disable amplitude sweep (Constant – only frequency sweep mode, or Table – frequency and amplitude sweep) or to define a custom excitation with JavaScript syntax
Line 151: Line 154:
   * **Offset:** Add a DC offset to the amplitude of the signal.  The range is -5 V to +5 V.   * **Offset:** Add a DC offset to the amplitude of the signal.  The range is -5 V to +5 V.
   * **Scale:** //Logarithmic// or //Linear//, defines the frequency scale used on the plot, as well as the method used to determine frequencies to be measured.   * **Scale:** //Logarithmic// or //Linear//, defines the frequency scale used on the plot, as well as the method used to determine frequencies to be measured.
-  * **Options:** Adjust the Amplification, Settle, Minimum number of periods, Average, Averaging, and Samples.+  * **Options:** Presents several additional less-commonly-used options, including the ability to adjust the Amplification, Settle time, Minimum number of periods, Average, Averaging, and number of Samples taken per frequency step.
  
 These settings can also be changed by clicking and dragging the plot or by using the mouse wheel - "panning" and "zooming" the plot. These settings can also be changed by clicking and dragging the plot or by using the mouse wheel - "panning" and "zooming" the plot.
Line 250: Line 253:
 */ */
  
-For more guides on how to use the Digilent Test and Measurement Device, return to the device's Resource Center, linked from the [[reference:test-and-measurement:start]] page of this wiki.+For more guides on how to use the Digilent Test and Measurement Device, return to the device's Resource Center, linked from the [[test-and-measurement:start]] page of this wiki.
  
-For more information on WaveForms visit the [[reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. +For more information on WaveForms visit the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. 
  
 For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums. For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums.