Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:guides:waveforms-impedance-analyzer [2021/05/14 23:05] – ↷ Page moved from reference:test-and-measurement:guides:waveforms-impedance-analyzer to test-and-measurement:guides:waveforms-impedance-analyzer Arthur Browntest-and-measurement:guides:waveforms-impedance-analyzer [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 11: Line 11:
 ===== Prerequisites ===== ===== Prerequisites =====
   * Digilent Test and Measurement Device with Analog Inputs and Outputs:   * Digilent Test and Measurement Device with Analog Inputs and Outputs:
 +    * [[test-and-measurement:analog-discovery-pro-5250:start|Analog Discovery Pro (ADP5250)]]
     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]
     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]
Line 17: Line 18:
   * Computer with WaveForms Software Installed   * Computer with WaveForms Software Installed
   * A Reference Circuit, which can be provided by:   * A Reference Circuit, which can be provided by:
-    * [[https://store.digilentinc.com/impedance-analyzer-for-analog-discovery/|Impedance Analyzer Adapter for Analog Discovery]], if using the Analog Discovery 2 or Analog Discovery (Legacy).+    * [[https://digilent.com/shop/impedance-analyzer-for-analog-discovery/|Impedance Analyzer Adapter for Analog Discovery]], if using the Analog Discovery 2 or Analog Discovery (Legacy).
     * A reference resistor appropriate for the specific load, as described in [[#using_the_impedance_analyzer1|Section 2]] of this document.     * A reference resistor appropriate for the specific load, as described in [[#using_the_impedance_analyzer1|Section 2]] of this document.
  
Line 70: Line 71:
 In this tutorial, the impedance of a 10nF capacitor is measured. Referring to the previous table, a 10kOhm reference resistor is required for this value of capacitance. Refer to the "Load First" diagram to the right for how to set up this circuit (the capacitor is the load and the reference resistor is the resistor in the diagram.)  In this tutorial, the impedance of a 10nF capacitor is measured. Referring to the previous table, a 10kOhm reference resistor is required for this value of capacitance. Refer to the "Load First" diagram to the right for how to set up this circuit (the capacitor is the load and the reference resistor is the resistor in the diagram.) 
  
-**Note:** //The Analog Input channels can be used with BNC Cables. For more information, see the [[reference:test-and-measurement:guides:waveforms-oscilloscope]] guide.//+**Note:** //The Analog Input channels can be used with BNC Cables. For more information, see the [[test-and-measurement:guides:waveforms-oscilloscope]] guide.//
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
Line 83: Line 84:
   * Ground (black wire) connected to the free end of the reference resistor   * Ground (black wire) connected to the free end of the reference resistor
  
-**Note:** //If desired, BNC Cables can be used to connect the Analog I/O channels to the circuit under test. This is discussed in detail in the [[reference:test-and-measurement:guides:waveforms-oscilloscope]] guide.//+**Note:** //If desired, BNC Cables can be used to connect the Analog I/O channels to the circuit under test. This is discussed in detail in the [[test-and-measurement:guides:waveforms-oscilloscope]] guide.//
 </WRAP> <WRAP column half> </WRAP> <WRAP column half>
 {{ :learn:instrumentation:tutorials:impan_example.jpg?direct&600 |}} {{ :learn:instrumentation:tutorials:impan_example.jpg?direct&600 |}}
Line 95: Line 96:
 ---- ----
  
-The [[https://store.digilentinc.com/impedance-analyzer-for-analog-discovery/|Impedance Analyzer Adapter for Analog Discovery]] makes use of the //Impedance Analyzer Instrument// easier. It automatically selects the best configuration for several reference resistors and relays to create a reference circuit to measure an unknown impedance.+The [[https://digilent.com/shop/impedance-analyzer-for-analog-discovery/|Impedance Analyzer Adapter for Analog Discovery]] makes use of the //Impedance Analyzer Instrument// easier. It automatically selects the best configuration for several reference resistors and relays to create a reference circuit to measure an unknown impedance.
  
 --> Click here if using the Impedance Analyzer Adapter for Analog Discovery # --> Click here if using the Impedance Analyzer Adapter for Analog Discovery #
Line 424: Line 425:
  
 ===== Other Resources ===== ===== Other Resources =====
-For more guides on how to use the Digilent Test and Measurement device, return to the device's Resource Center, linked from the [[reference:test-and-measurement:start]] page of this wiki.+For more guides on how to use the Digilent Test and Measurement device, return to the device's Resource Center, linked from the [[test-and-measurement:start]] page of this wiki.
  
-For more information on WaveForms, visit the [[reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. +For more information on WaveForms, visit the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. 
  
 For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums. For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums.