Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:guides:complementary-labs:lab2:start [2021/05/14 23:05] – ↷ Page moved from reference:test-and-measurement:guides:complementary-labs:lab2:start to test-and-measurement:guides:complementary-labs:lab2:start Arthur Browntest-and-measurement:guides:complementary-labs:lab2:start [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 27: Line 27:
 <WRAP column half> <WRAP column half>
 **Hardware** **Hardware**
-  * [[https://store.digilentinc.com/analog-discovery-studio-a-portable-circuits-laboratory-for-every-student/|Analog Discovery Studio]] +  * [[https://digilent.com/shop/analog-discovery-studio-a-portable-circuits-laboratory-for-every-student/|Analog Discovery Studio]] 
-  * [[https://store.digilentinc.com/breadboard-canvas/|Breadboard Canvas]]+  * [[https://digilent.com/shop/breadboard-canvas/|Breadboard Canvas]]
   * 1μF electrolytic capacitor   * 1μF electrolytic capacitor
   * 0.1μF ceramic capacitor   * 0.1μF ceramic capacitor
Line 37: Line 37:
 **Software** **Software**
   * [[https://www.multisim.com/|Multisim Live]]   * [[https://www.multisim.com/|Multisim Live]]
-  * [[reference:software:waveforms:waveforms-3:start|]]+  * [[software:waveforms:waveforms-3:start]]
 </WRAP></WRAP> </WRAP></WRAP>
 ---- ----
Line 92: Line 92:
 <WRAP group> <WRAP group>
   * Design a filter with a cut-off frequency of 1kHz. Verify your design by using Multisim. What resistor and capacitor did you use?   * Design a filter with a cut-off frequency of 1kHz. Verify your design by using Multisim. What resistor and capacitor did you use?
-  * Build the low-pass filter from [[reference:test-and-measurement:guides:complementary-labs:lab1:start]] using Multisim and then run the AC Sweep analysis. Determine the output magnitude and phase when the input frequency is: 1Hz, 10Hz, 100Hz, 1kHz, and 100kHz. Compare your calculation with the simulation results.+  * Build the low-pass filter from [[test-and-measurement:guides:complementary-labs:lab1:start]] using Multisim and then run the AC Sweep analysis. Determine the output magnitude and phase when the input frequency is: 1Hz, 10Hz, 100Hz, 1kHz, and 100kHz. Compare your calculation with the simulation results.
   * Set the Grapher vertical scale to Logarithmic and keep the horizontal scale as Decade in Multisim Live (these settings are accessible through the Configuration Pane in the Grapher window). Note that a decade is a factor of 10 difference between two numbers. For example, 1 to 10 is one decade and 10 to 100 is another decade. What is the slope of the RC filter expressed as dB/decade?   * Set the Grapher vertical scale to Logarithmic and keep the horizontal scale as Decade in Multisim Live (these settings are accessible through the Configuration Pane in the Grapher window). Note that a decade is a factor of 10 difference between two numbers. For example, 1 to 10 is one decade and 10 to 100 is another decade. What is the slope of the RC filter expressed as dB/decade?
 </WRAP> </WRAP>
Line 117: Line 117:
 </WRAP> </WRAP>
  
-<html><iframe width="1170" height="600" src="https://www.multisim.com/content/MUPrYtAh3MbqkCFW4fhFPd/lab-2-active-and-passive-filters-2nd-order-lpf/open"></iframe></html>+<html><iframe width="100%" height="600" src="https://www.multisim.com/content/MUPrYtAh3MbqkCFW4fhFPd/lab-2-active-and-passive-filters-2nd-order-lpf/open"></iframe></html>
  
 --> Questions and Exercises # --> Questions and Exercises #
Line 147: Line 147:
 </WRAP> </WRAP>
  
-<html><iframe width="1170" height="600" src="https://www.multisim.com/content/kW9GXgTr4EDCobm6Ec8AY4/lab-2-active-and-passive-filters-active-lpf/open"></iframe></html>+<html><iframe width="100%" height="600" src="https://www.multisim.com/content/kW9GXgTr4EDCobm6Ec8AY4/lab-2-active-and-passive-filters-active-lpf/open"></iframe></html>
  
 --> Questions and Exercises # --> Questions and Exercises #
Line 197: Line 197:
 ==== Active Filter ==== ==== Active Filter ====
 <WRAP group><WRAP half column> <WRAP group><WRAP half column>
-Build the circuit presented in [[reference:test-and-measurement:guides:complementary-labs:lab2:start#active_filter|Active Filter]] on the Breadboard Canvas. You will need to power the opamp with ±5V, from the variable power supply (red and white wires). Connect the function generator's W1 channel (yellow wire) and the oscilloscope's Channel 1+ (orange wire) to the input of the circuit and the 2+ channel of the oscilloscope (blue wire) to the output of the circuit. Connect to the ground the 1- and 2- channels of the oscilloscope (orange-white and blue-white wires), the function generator's ground and the positive input of the opamp. +Build the circuit presented in [[test-and-measurement:guides:complementary-labs:lab2:start#active_filter|Active Filter]] on the Breadboard Canvas. You will need to power the opamp with ±5V, from the variable power supply (red and white wires). Connect the function generator's W1 channel (yellow wire) and the oscilloscope's Channel 1+ (orange wire) to the input of the circuit and the 2+ channel of the oscilloscope (blue wire) to the output of the circuit. Connect to the ground the 1- and 2- channels of the oscilloscope (orange-white and blue-white wires), the function generator's ground and the positive input of the opamp. 
  
 Don't forget to turn the Scope Channel 1 and Scope Channel 2 switches towards the MTE headers and the V+ switch towards the **POWER** inscription. Don't forget to turn the Scope Channel 1 and Scope Channel 2 switches towards the MTE headers and the V+ switch towards the **POWER** inscription.
Line 241: Line 241:
 </WRAP> </WRAP>
  
-<html><iframe width="1170" height="600" src="https://www.multisim.com/content/JbKBk3vvyii89vCB3PypJj/lab-2-active-and-passive-filters-butterworthchebyshev-lpf/open"></iframe></html>+<html><iframe width="100%" height="600" src="https://www.multisim.com/content/JbKBk3vvyii89vCB3PypJj/lab-2-active-and-passive-filters-butterworthchebyshev-lpf/open"></iframe></html>
  
 ---- ----
Line 247: Line 247:
 ===== Next Steps ===== ===== Next Steps =====
  
-For more complementary laboratories, return to the [[reference:test-and-measurement:guides:complementary-labs:start]] page of this wiki.+For more complementary laboratories, return to the [[test-and-measurement:guides:complementary-labs:start]] page of this wiki.
  
-For technical support, please visit the [[https://forum.digilentinc.com/forum/8-scopes-instruments/|Scopes and Instruments]] section of the Digilent Forums.+For technical support, please visit the [[https://forum.digilentinc.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums.