Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| test-and-measurement:discovery-power-supply-3340:specifications [2022/04/04 00:26] – Keith M Kolmos | test-and-measurement:discovery-power-supply-3340:specifications [2022/10/04 11:38] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Discovery Power Supply (DPS3340) Specifications ====== | ====== Discovery Power Supply (DPS3340) Specifications ====== | ||
| + | <WRAP round todo> | ||
| + | === Under Construction! === | ||
| + | </ | ||
| + | |||
| ~~TechArticle~~ | ~~TechArticle~~ | ||
| - | These specifications are valid following | + | These specifications are valid following |
| - | ===== Triple Output | + | ===== Power Supplies |
| + | All channels are independently controllable with independent current and voltage settings. | ||
| + | |<100% 15% 15%>| | ||
| + | ^ Specification | ||
| + | ^ DC Output Rating | ||
| + | | ::: | **Current** | ||
| + | ^ Maximum Power | ||
| + | | ::: | ||
| + | ^ DC Accuracy | ||
| + | | ::: | **Current** | ||
| + | ^ Load Regulation | ||
| + | | ::: | **Current** | ||
| + | ^ Line Regulation | ||
| + | | ::: | **Current** | ||
| + | ^ Ripple and Noise | **Voltage** \\ (20 MHz Bandwidth): | ||
| + | | ::: | ::: | ::: | ::: | ::: | | ||
| + | | ::: | **Current** \\ (20 MHz Bandwidth): | ||
| + | ^ Setting Resolution | ||
| + | | ::: | **Current** | ||
| + | ^ Meter Resolution | ||
| + | | ::: | **Current** (across -Imax....+Imax interval) | ||
| + | ^ Meter Accuracy | ||
| + | | ::: | **Current** | ||
| - | ====Digital Power Supply==== | + | === Isolation Voltage |
| + | Device isolated from network through external supply. Outputs share a common GND between them and with the host PCB USB connector. | ||
| - | * **Output 1** | + | === Protection Circuitry === |
| - | + | All three supplies feature overcurrent protection through software-settable current limits that can be applied individually to each channel. Same-polarity aggressor protection and reverse voltage protection work up to ±15 V. | |
| - | |<100% 40%>| | + | |
| - | ^ Voltage | 5.0 V ± 10% | | + | |
| - | ^ Current | 3 A | | + | |
| - | * **Output | + | === Tracking Mode === |
| - | + | When the software-implemented tracking mode is active, Outputs | |
| - | |<100% 40%>| | + | |
| - | ^ Voltage | 15.0 V ± 10% | | + | |
| - | ^ Current | 500 mA | | + | |
| - | + | ||
| - | * **Output | + | |
| - | + | ||
| - | |<100% 40%>| | + | |
| - | ^ Voltage | -15.0 V ± 10% | | + | |
| - | ^ Current | 500 mA | | + | |
| + | ~~REFNOTES~~ | ||
| ---- | ---- | ||
| + | ===== Connectivity ===== | ||
| + | The DPS3340 requires a host computer running the WaveForms software connected via USB to operate. | ||
| - | ==== DC Power Supply Isolation Voltages ==== | + | ^ Device |
| - | |<100% 25%>| | + | |
| - | ^ +25V and -25V to earth ground, continuous | + | |
| - | + | ||
| - | **Note:** // | + | |
| ---- | ---- | ||
| - | =====Environmental===== | + | ===== Power Requirements |
| - | |<100% 25%>| | + | The DPS3340 requires an auxiliary power supply. |
| - | ^ Operating Temperature | 0 °C to 40 °C || | + | |
| - | ^ Storage Temperature | -20 °C to 60 °C || | + | |
| - | ^ Operating Humidity | 10% to 90% RH, non-condensing \\ DMM full accuracy at 10% to 80% || | + | |
| - | ^ Storage Humidity | 5% to 95% RH, non-condensing || | + | |
| - | ^ Cooling | Forced air circulation (positive pressurization) through a fan. Fan speed automatically adjusts according to operating conditions. Intake and exhaust locations are on rear of device. Ensure that the intake and exhaust locations are not obstructed. || | + | |
| - | ^ Pollution Degree | 2 || | + | |
| - | ^ Maximum Altitude | 2,000 m || | + | |
| - | **Note:** For indoor use only. | + | ^ Power Supply Voltage |
| + | ^ Power Supply Current | ||
| + | ^ Power Consumption | ||
| + | ^ Barrel Connector Size | 5.5 mm x 1.65 mm | | ||
| ---- | ---- | ||
| + | ===== Physical Characteristics ===== | ||
| + | |<100% 25%>| | ||
| + | ^ Dimensions | ||
| + | ^ Weight | ||
| + | |||
| + | ---- | ||
| + | ===== Environmental ===== | ||
| - | ==== Shock and Vibration ==== | ||
| |<100% 25%>| | |<100% 25%>| | ||
| - | ^ Operational Shock | 30 g peak, half sine, 11 ns pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) || | + | ^ Operating Temperature |
| - | ^ Random Vibration (Operating) | 5 Hz to 500 Hz, 0.3 g< | + | ^ Storage Temperature |
| - | ^ Random Vibration (Nonoperating) | + | ^ Operating |
| + | ^ Storage Humidity | ||
| + | ^ Cooling | ||
| + | ^ Pollution Degree | ||
| + | ^ Maximum Altitude | ||
| + | Indoor use only | ||
| + | ~~REFNOTES~~ | ||
| + | ---- | ||
| + | ===== Certifications ===== | ||
| ---- | ---- | ||
| - | {{page> | ||

