Line 322: Line 322:
 ---- ----
 ===== Power Requirements ===== ===== Power Requirements =====
-|<100% 25%> +|<100% 25%>| 
-  +^ Voltage Input Range | 100 V AC to 240 V AC, ±10%, 50/60 Hz ||
-^ Voltage Input Range | 100 V AC to 240 V AC, 50/60 Hz ||+
 ^ Power Consumption | 100 W maximum || ^ Power Consumption | 100 W maximum ||
 ^ Power Input Connector | IEC C13 power connector ||  ^ Power Input Connector | IEC C13 power connector || 
Line 347: Line 346:
  
 ==== DMM Isolation Voltages (Ground to Earth) ==== ==== DMM Isolation Voltages (Ground to Earth) ====
 +
 +<columns 100% 5% 95%>
 +{{:test-and-measurement:analog-discovery-pro-5250:hazard.png?40}}
 +<newcolumn>
 +**Hazardous Voltage:** This icon denotes a warning advising you to take precautions to avoid electrical shock.
 +</columns>
 +
 +=== Channel-to-earth Ground ===
 |<100% 25%>| |<100% 25%>|
 ^ Continuous | 300 V, Measurement Category II || ^ Continuous | 300 V, Measurement Category II ||
Line 354: Line 361:
  
 Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe.
 +
 +<columns 100% 5% 95%>
 +{{:test-and-measurement:analog-discovery-pro-5250:caution.png?40}}
 +<newcolumn>
 +**Caution:** Do not connect the ADP5250 hardware to signals or use for measurements within Measurement Categories III or IV.
 +</columns>
  
 ==== DC Power Supply Isolation Voltages ==== ==== DC Power Supply Isolation Voltages ====
 |<100% 25%>| |<100% 25%>|
-^ +25V and -25V to earth ground, continuous | 60VDC, Measurement Category 1 |||+^ +25V and -25V to earth ground, continuous | 60 VDC, Measurement Category 1 ||| 
 + 
 +**Note:** //Measurement Categories CAT I and CAT O (Other) are equivalent. The input circuits are not intended for direct connection to the MAINs building installations of Categories CAT II, CAT III, or CAT IV.//
  
 ---- ----