 ====== Analog Discovery Pro (ADP3450/ADP3250) Specifications ====== ====== Analog Discovery Pro (ADP3450/ADP3250) Specifications ======
 ~~TechArticle~~ ~~TechArticle~~
-These specifications are valid following 30 minutes of warmup and are typical at 25 °C unless otherwise noted.+These specifications are valid following 30 minutes of warm-up and are typical at 25 °C unless otherwise noted.
  
 ===== Mixed Signal Oscilloscope ===== ===== Mixed Signal Oscilloscope =====
Line 22: Line 22:
 ^ AC Coupling Cut-off Frequency                                                                                                                                                                                                                                                                                                                                                                              | 12 Hz at -3 dB                                                                                                            || ^ AC Coupling Cut-off Frequency                                                                                                                                                                                                                                                                                                                                                                              | 12 Hz at -3 dB                                                                                                            ||
 ^ Absolute Resolution                                                                                                                                                                                                                                                                                                                                                                                        | 0.125 mV (scale ≤ 200 mV/div) \\ 3.05 mV (scale > 200 mV/div)                                                             || ^ Absolute Resolution                                                                                                                                                                                                                                                                                                                                                                                        | 0.125 mV (scale ≤ 200 mV/div) \\ 3.05 mV (scale > 200 mV/div)                                                             ||
-^ Accuracy (DC to 1kHz, Integrative measurements)[(Average, High, Low, Middle, Amplitude, AC RMS, DC RMS are integrative measurements; they include average mechanisms which reduce the effect of noise and short pulses (overshoots, undershoots). Max, Min, Pk2Pk, Overshoot, RiseOvershoot, FallOvershoot are sample based measurements, affected by noise and short pulses (overshoots, undershoots).)]  | ±10 mV ± 0.5%  (scale ≤ 200 mV/div, VinCM = 0 V) \\ ±100 mV ± 0.5% (scale > 200 mV/div, VinCM = 0 V)                      ||+^ Accuracy (DC to 1 kHz, Integrative measurements)[(Average, High, Low, Middle, Amplitude, AC RMS, DC RMS are integrative measurements; they include average mechanisms which reduce the effect of noise and short pulses (overshoots, undershoots). Max, Min, Pk2Pk, Overshoot, RiseOvershoot, FallOvershoot are sample based measurements, affected by noise and short pulses (overshoots, undershoots).)]  | ±10 mV ± 0.5%  (scale ≤ 200 mV/div, VinCM = 0 V) \\ ±100 mV ± 0.5% (scale > 200 mV/div, VinCM = 0 V)                      ||
 ^ Input Range                                                                                                                                                                                                                                                                                                                                                                                                | ±25 V with respect to ground (50 V peak-to-peak)                                                                          || ^ Input Range                                                                                                                                                                                                                                                                                                                                                                                                | ±25 V with respect to ground (50 V peak-to-peak)                                                                          ||
 ^ Vertical Sensitivity (range)                                                                                                                                                                                                                                                                                                                                                                               | 500 µV/div to 5 V/div (10 ranges)                                                                                         || ^ Vertical Sensitivity (range)                                                                                                                                                                                                                                                                                                                                                                               | 500 µV/div to 5 V/div (10 ranges)                                                                                         ||
Line 302: Line 302:
 ---- ----
  
-{{page>test-and-measurement:analog-discovery-pro-3x50:certifications&fullpage}}+{{page>test-and-measurement:analog-discovery-pro-3x50:certifications&fullpage&noindent}}