Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:analog-discovery-pro-3x50:oversampling [2021/05/14 23:04] – ↷ Page moved from reference:test-and-measurement:analog-discovery-pro-3x50:oversampling to test-and-measurement:analog-discovery-pro-3x50:oversampling Arthur Browntest-and-measurement:analog-discovery-pro-3x50:oversampling [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 29: Line 29:
 </columns> </columns>
 ---- ----
-{{section>reference:test-and-measurement:analog-discovery-pro-3x50:change-max-sample-rate#without_dropdown&noheader}}+{{section>test-and-measurement:analog-discovery-pro-3x50:change-max-sample-rate#without_dropdown&noheader}}
  
 <columns 100% 50% 50%> <columns 100% 50% 50%>
Line 55: Line 55:
 {{ reference:test-and-measurement:analog-discovery-pro-3x50:oversampling-trigger.png?800 |}} {{ reference:test-and-measurement:analog-discovery-pro-3x50:oversampling-trigger.png?800 |}}
  
-The best trigger conditions to use heavily depend on the signal being acquired. For more information on the use of triggers, refer to the [[reference:test-and-measurement:guides:waveforms-external-triggers]] and [[reference:test-and-measurement:guides:waveforms-cross-triggers]] guides.+The best trigger conditions to use heavily depend on the signal being acquired. For more information on the use of triggers, refer to the [[test-and-measurement:guides:waveforms-external-triggers]] and [[test-and-measurement:guides:waveforms-cross-triggers]] guides.
 ---- ----
 <columns 100% 50% 50%> <columns 100% 50% 50%>
 Finally, you can check the sample rate and number of samples indicators to see the settings used for the capture currently displayed on the plot pane. "2048 samples at 500 MHz &4" means that the combined oversampled capture has 2048 total samples, a sample rate of 500 MS/s (0.5 GS/s), and consists of four individual captures. This capture was taken with an oversampling factor of 4, 512 samples per capture, and at a 125 MS/s sample rate. Finally, you can check the sample rate and number of samples indicators to see the settings used for the capture currently displayed on the plot pane. "2048 samples at 500 MHz &4" means that the combined oversampled capture has 2048 total samples, a sample rate of 500 MS/s (0.5 GS/s), and consists of four individual captures. This capture was taken with an oversampling factor of 4, 512 samples per capture, and at a 125 MS/s sample rate.
 <newcolumn> <newcolumn>
-{{ oversampling-capture-indicator.png?400 |}}+{{ reference:test-and-measurement:analog-discovery-pro-3x50:oversampling-capture-indicator.png?400 |}}
 </columns> </columns>
 ---- ----
Line 78: Line 78:
 Check the [[start|Analog Discovery Pro (ADP3450/ADP3250) Resource Center]] for more guides on using your device. Check the [[start|Analog Discovery Pro (ADP3450/ADP3250) Resource Center]] for more guides on using your device.
  
-For more information on the Oscilloscope instrument, refer to [[reference:test-and-measurement:guides:waveforms-oscilloscope]]+For more information on the Oscilloscope instrument, refer to [[test-and-measurement:guides:waveforms-oscilloscope]]