software:digilent-instrumentation-protocol:oscilloscope [2021/05/14 23:05] – ↷ Page moved from reference:software:digilent-instrumentation-protocol:oscilloscope to software:digilent-instrumentation-protocol:oscilloscope Arthur Brownsoftware:digilent-instrumentation-protocol:oscilloscope [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 16: Line 16:
     * **#** - (Array<Object>) - An array of command objects applied to the oscilloscope channel.     * **#** - (Array<Object>) - An array of command objects applied to the oscilloscope channel.
       * **command** - (String) - The Get Current State command: “getCurrentState”       * **command** - (String) - The Get Current State command: “getCurrentState”
-      * **statusCode** - (Integer) - A numeric value representing the device status.  See [[reference/software/digilent-instrumentation-protocol/status-codes]]+      * **statusCode** - (Integer) - A numeric value representing the device status.  See [[software:digilent-instrumentation-protocol:status-codes]]
       * **wait** - (Integer) - The number of ms to wait before the device is ready to process another command.          * **wait** - (Integer) - The number of ms to wait before the device is ready to process another command.   
       * **state** - (String) - The state of the instrument channel: "armed", "acquiring", "idle", or "triggered".       * **state** - (String) - The state of the instrument channel: "armed", "acquiring", "idle", or "triggered".
Line 83: Line 83:
     * **#** - (Array<Object>) - An array of command objects applied to the oscilloscope channel.     * **#** - (Array<Object>) - An array of command objects applied to the oscilloscope channel.
       * **command** - (String) - The Read command: “read”.       * **command** - (String) - The Read command: “read”.
-      * **statusCode** - (Integer) - A numeric value representing the device status.  See [[reference/software/digilent-instrumentation-protocol/status-codes]]+      * **statusCode** - (Integer) - A numeric value representing the device status.  See [[software:digilent-instrumentation-protocol:status-codes]]
       * **wait** - (Integer) - The number of ms to wait before the device is ready to process another command.          * **wait** - (Integer) - The number of ms to wait before the device is ready to process another command.   
       * **binaryOffset** - (Integer) - The first byte of the buffer in the binary data chunk.       * **binaryOffset** - (Integer) - The first byte of the buffer in the binary data chunk.
Line 164: Line 164:
     * **#** - (Array<Object>) - An array of command objects applied to the oscilloscope channel.     * **#** - (Array<Object>) - An array of command objects applied to the oscilloscope channel.
       * **command** - (String) - The Set Parameters command: “setParameters”       * **command** - (String) - The Set Parameters command: “setParameters”
-      * **statusCode** - (Integer) - A numeric value representing the device status.  See [[reference/software/digilent-instrumentation-protocol/status-codes]]+      * **statusCode** - (Integer) - A numeric value representing the device status.  See [[software:digilent-instrumentation-protocol:status-codes]]
       * **actualVOffset** - (Integer) - The actual voltage offset used in mV.       * **actualVOffset** - (Integer) - The actual voltage offset used in mV.
       * **actualSampleFreq**- (Integer) - The actual sample frequency used in mHz.       * **actualSampleFreq**- (Integer) - The actual sample frequency used in mHz.