Differences
This shows you the differences between two versions of the page.
| programmable-logic:guides:labview [2021/06/09 18:13] – Arthur Brown | programmable-logic:guides:labview [2022/10/04 11:38] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 243: | Line 243: | ||
| * The demo is configured to read over SPI or I2C protocol and to read/write over UART protocol. | * The demo is configured to read over SPI or I2C protocol and to read/write over UART protocol. | ||
| * The SPI is configured to read one byte by sending a multibyte structure (3 bytes) wherein the first byte is a command, the second byte is the SPI Register Address and the third byte is 0x00. The user must adapt the block diagram | * The SPI is configured to read one byte by sending a multibyte structure (3 bytes) wherein the first byte is a command, the second byte is the SPI Register Address and the third byte is 0x00. The user must adapt the block diagram | ||
| - | * The A6-A7 differential channel is a unipolar channel and A8-A9, A10-A11 and V_P – V_N are bipolar channels. Please read the [[https://www.xilinx.com/ | + | * The A6-A7 differential channel is a unipolar channel and A8-A9, A10-A11 and V_P – V_N are bipolar channels. Please read the [[https://docs.xilinx.com/ |
| ---- | ---- | ||
| Line 298: | Line 298: | ||
| | **38** | | **38** | ||
| | **Analog Input channels** | | **Analog Input channels** | ||
| - | | **0** | A0 | Single-Ended Analog Unipolar Inputs (range of 0V-3.3V). Arty Z7 uses an external circuit to scale down the input voltage from 0V-3.3V to an input range of 0V to 1V. (see [[https://www.xilinx.com/ | + | | **0** | A0 | Single-Ended Analog Unipolar Inputs (range of 0V-3.3V). Arty Z7 uses an external circuit to scale down the input voltage from 0V-3.3V to an input range of 0V to 1V. (see [[https://docs.xilinx.com/ |
| | **1** | A1 | ::: | | | **1** | A1 | ::: | | ||
| | **2** | A2 | ::: | | | **2** | A2 | ::: | | ||
| Line 304: | Line 304: | ||
| | **4** | A4 | ::: | | | **4** | A4 | ::: | | ||
| | **5** | A5 | ::: | | | **5** | A5 | ::: | | ||
| - | | **67** | + | | **67** |
| | **89** | | **89** | ||
| | **111** | | **111** | ||
| Line 436: | Line 436: | ||
| | **24** | | **24** | ||
| | **Analog Input channels** | | **Analog Input channels** | ||
| - | | **0** | A0 | Single-Ended Analog Unipolar Inputs (range of 0V-3.3V). Arty Z7 uses an external circuit to scale down the input voltage from 0V-3.3V to an input range of 0V to 1V. (see [[https://www.xilinx.com/ | + | | **0** | A0 | Single-Ended Analog Unipolar Inputs (range of 0V-3.3V). Arty Z7 uses an external circuit to scale down the input voltage from 0V-3.3V to an input range of 0V to 1V. (see [[https://docs.xilinx.com/ |
| | **1** | A1 | ::: | | | **1** | A1 | ::: | | ||
| | **2** | A2 | ::: | | | **2** | A2 | ::: | | ||
| Line 442: | Line 442: | ||
| | **4** | A4 | ::: | | | **4** | A4 | ::: | | ||
| | **5** | A5 | ::: | | | **5** | A5 | ::: | | ||
| - | | **67** | + | | **67** |
| | **89** | | **89** | ||
| | **111** | | **111** | ||
| Line 580: | Line 580: | ||
| | **24** | | **24** | ||
| | **Analog Input channels** | | **Analog Input channels** | ||
| - | | **0** | A0 | Single-Ended Analog Unipolar Inputs (range of 0V-3.3V). Cora Z7 uses an external circuit to scale down the input voltage from 0V-3.3V to an input range of 0V to 1V. (see [[https://www.xilinx.com/ | + | | **0** | A0 | Single-Ended Analog Unipolar Inputs (range of 0V-3.3V). Cora Z7 uses an external circuit to scale down the input voltage from 0V-3.3V to an input range of 0V to 1V. (see [[https://docs.xilinx.com/ |
| | **1** | A1 | ::: | | | **1** | A1 | ::: | | ||
| | **2** | A2 | ::: | | | **2** | A2 | ::: | | ||
| Line 586: | Line 586: | ||
| | **4** | A4 | ::: | | | **4** | A4 | ::: | | ||
| | **5** | A5 | ::: | | | **5** | A5 | ::: | | ||
| - | | **67** | + | | **67** |
| | **89** | | **89** | ||
| | **111** | | **111** | ||

