Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
programmable-logic:eclypse-z7:demos:zmod-scope [2021/11/19 00:33] – Arthur Brownprogrammable-logic:eclypse-z7:demos:zmod-scope [2022/10/04 11:38] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== Using the Zmod Scope 1410-105 with the Zmod Library and Eclypse Z7 ====== ====== Using the Zmod Scope 1410-105 with the Zmod Library and Eclypse Z7 ======
- 
-<WRAP round todo> 
-== Under Construction == 
-</WRAP> 
  
 {{ :programmable-logic:eclypse-z7:demos:sw-demo-hw-setup.png?600 |}} {{ :programmable-logic:eclypse-z7:demos:sw-demo-hw-setup.png?600 |}}
Line 22: Line 18:
     * //See [[vivado/getting_started/start]] for installation instructions.//     * //See [[vivado/getting_started/start]] for installation instructions.//
   * PetaLinux Installation compatible with the latest release of this demo (2019.1)   * PetaLinux Installation compatible with the latest release of this demo (2019.1)
-    * //See Xilinx's [[https://www.xilinx.com/support/documentation/sw_manuals/xilinx2019_1/ug1144-petalinux-tools-reference-guide.pdf|PetaLinux Tools Documentation (2019.1) (UG1144)]] for installation instructions.//+    * //See Xilinx's [[https://docs.xilinx.com/v/u/2019.1-English/ug1144-petalinux-tools-reference-guide|PetaLinux Tools Documentation (2019.1) (UG1144)]] for installation instructions.//
     * Only required if you want to rebuild the PetaLinux image     * Only required if you want to rebuild the PetaLinux image
   * Serial Terminal application to receive messages printed by the demo   * Serial Terminal application to receive messages printed by the demo
     * //See [[programmable-logic:guides:serial-terminals:start]] for more information.//     * //See [[programmable-logic:guides:serial-terminals:start]] for more information.//
 +  * Git is required to download the sources
  
   * A power supply for external power   * A power supply for external power
Line 46: Line 43:
 Some stimulus should be provided to the Zmod Scope's CH1 SMA connector. The demo, without user modification, performs a capture immediately, providing a 1024-sample, 10 us long, buffer of data to the host. Some stimulus should be provided to the Zmod Scope's CH1 SMA connector. The demo, without user modification, performs a capture immediately, providing a 1024-sample, 10 us long, buffer of data to the host.
  
-The results shown later in this document were produced by connecting CH1 to the first waveform generator channel of an [[test-and-measurement:analog-discovery-pro-adp3x50|Analog Discovery Pro (ADP3450)]] via a BNC cable and a BNC-to-SMA adapter.+The results shown later in this document were produced by connecting CH1 to the first waveform generator channel of an [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450)]] via a BNC cable and a BNC-to-SMA adapter.
 ---- ----
  
Line 67: Line 64:
 ---- ----
 <WRAP group> <WRAP column half> <WRAP group> <WRAP column half>
-When the project is run, data will be printed to a connected serial terminal, as seen in the screenshot to the right.+When the project is run, data will be printed to a connected serial terminal, as seen in the screenshot to the right. The data is printed in both volts and 14-bit raw twos-complement form, along with the time since the start of the buffer, tab-separated.
  
 When using the Linux project, the same data is written to a CSV file, which can be found in the ''/home/eclypse'' directory of the Eclypse's filesystem. When using the Linux project, the same data is written to a CSV file, which can be found in the ''/home/eclypse'' directory of the Eclypse's filesystem.