<?xml version="1.0" encoding="UTF-8"?>
<!-- generator="FeedCreator 1.8" -->
<?xml-stylesheet href="https://dev-wiki.digilent.com/lib/exe/css.php?s=feed" type="text/css"?>
<rdf:RDF
    xmlns="http://purl.org/rss/1.0/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
    xmlns:dc="http://purl.org/dc/elements/1.1/">
    <channel rdf:about="https://dev-wiki.digilent.com/feed.php">
        <title>Digilent Reference learn:instrumentation:tutorials:openscope-mz</title>
        <description></description>
        <link>https://dev-wiki.digilent.com/</link>
        <image rdf:resource="https://dev-wiki.digilent.com/ttps://dev-wiki.digilent.com/lib/tpl/digilent-tpl/images/favicon.ico" />
       <dc:date>2026-10-23T08:18:17+00:00</dc:date>
        <items>
            <rdf:Seq>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/calibration?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/getting-started?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/gpio-logic-analyzer?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/instrument-panel?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/math-and-cursors?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/offline-support?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/oscilloscope?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/power-supply?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/setup?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/start?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/triggers?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/update-firmware?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/wavegen?rev=1664883525&amp;do=diff"/>
                <rdf:li rdf:resource="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/wifi-setup?rev=1664883525&amp;do=diff"/>
            </rdf:Seq>
        </items>
    </channel>
    <image rdf:about="https://dev-wiki.digilent.com/ttps://dev-wiki.digilent.com/lib/tpl/digilent-tpl/images/favicon.ico">
        <title>Digilent Reference</title>
        <link>https://dev-wiki.digilent.com/</link>
        <url>https://dev-wiki.digilent.com/ttps://dev-wiki.digilent.com/lib/tpl/digilent-tpl/images/favicon.ico</url>
    </image>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/calibration?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Calibration</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/calibration?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Calibration

The OpenScope MZ uses software calibration to improve measurement accuracy and each OpenScope MZ is calibrated as part of the manufacturing process.  The OpenScope MZ does not need to be re-calibrated before each use, however, calibration is recommended before the first use and when changing environments, especially if there is a large temperature variation between environments.</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/getting-started?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>Getting Started with the OpenScope MZ</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/getting-started?rev=1664883525&amp;do=diff</link>
        <description>Getting Started with the OpenScope MZ

Despite our hopes and effort to create an innovative and low-cost T&amp;M solution, we’ve received consistent negative feedback on the OpenScope MZ and OpenLogger regarding overall reliability that has led us to determine that it is not up to our high standards for our test and measurement products.</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/gpio-logic-analyzer?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - GPIO and Logic Analyzer</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/gpio-logic-analyzer?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - GPIO and Logic Analyzer

OpenScope MZ has 10 3.3v logic digital channels each capable of sourcing 7mA and sinking 12mA.  Each channel can be independently configured as general purpose I/O or as a logic analyzer channel.  Logic analyzer channels can be sampled at up to 10</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/instrument-panel?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Instrument Panel</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/instrument-panel?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Instrument Panel

----------

The instrument panel provides access to core device functionality and enables the user to configure the triggers, oscilloscope,  wavegen, logic analyzer, gpio, and power supplies, manipulate the cart, acquire samples and more.</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/math-and-cursors?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Math and Cursors</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/math-and-cursors?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Math and Cursors

Math

----------

The math menu allows users to enable and disable various automatic calculations like signal frequency, amplitude, etc.

	*  Channel - The input channel to use as the signal source for the operation.</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/offline-support?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Offline Support</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/offline-support?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Offline Support

When using OpenScope MZ it is recommended to use the version of WaveForms live hosted at www.waveformslive.com as it will always provide the most current released version of the WaveForms Live software.  However when internet access is not available there several alternative was to use the WaveForms Live software.</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/oscilloscope?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Oscilloscope</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/oscilloscope?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Oscilloscope

The OpenScope MZ has two 12-bit oscilloscope channels each capable of sampling ±20V at 6.25MS/s with 2 MHz bandwidth.

instrumentation tutorial openscope-mz oscilloscope</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/power-supply?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Power Supply</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/power-supply?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Power Supply

OpenScope MZ has two DC power supply channel each independently configurable with a range of ±4V and capable of supplying 50mA.  

instrumentation tutorial openscope-mz power-supply</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/setup?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Setup</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/setup?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Setup

Setup the Digilent Agent

----------

The  Digilent Agent is a service that runs in the system tray on Windows, Mac, or Linux and enables WaveForms Live to communicate with Digilent hardware. The Digilent Agent makes it easy to update the OpenScope MZ's firmware, configure Wifi and calibrate the instruments.</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/start?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ (Redirect)</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/start?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ (Redirect)</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/triggers?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Triggers</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/triggers?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Triggers

OpenScope MZ can be configured to trigger on any oscilloscope or logic analyzer channel.  Users can configure trigger type (rising / falling / don't care) and the trigger threshold (oscilloscope only).

instrumentation tutorial openscope-mz triggers</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/update-firmware?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Update Firmware</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/update-firmware?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Update Firmware

Setup the Digilent Agent

----------

The  Digilent Agent is a service that runs in the system tray on Windows, Mac, or Linux and enables WaveForms Live to communicate with Digilent hardware. The Digilent Agent makes it easy to update the OpenScope MZ's firmware, configure Wifi and calibrate the instruments.</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/wavegen?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Function Generator</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/wavegen?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Function Generator

The OpenScope MZ has one function generator channel that can generate 10-bit analog values at up to 10 MS/s with a range of 3V peak-to-peak and offset of ±1.5V.

instrumentation tutorial openscope-mz wavegen function-generator</description>
    </item>
    <item rdf:about="https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/wifi-setup?rev=1664883525&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-10-04T11:38:45+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>OpenScope MZ - Wifi Setup</title>
        <link>https://dev-wiki.digilent.com/learn/instrumentation/tutorials/openscope-mz/wifi-setup?rev=1664883525&amp;do=diff</link>
        <description>OpenScope MZ - Wifi Setup

WaveForms Live provides a graphical user interface for configuring network adapters on WaveForms Live compatible devices.  When configuring network adapter settings it is recommended to connect to the device using the Digilent Agent, however some, but not all, network settings can be changed while connected via Wifi or ethernet.</description>
    </item>
</rdf:RDF>
