Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| dmc-60c:hardware-reference-manual [2018/11/12 22:59] – Arthur Brown | dmc-60c:hardware-reference-manual [2022/10/04 11:38] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ====== DMC60C | + | ====== DMC60C Reference Manual ====== |
| - | /* | + | <WRAP round info 650px> |
| - | Input voltage monitoring was removed | + | ===Note=== |
| - | So section 8 is removed | + | The DMC60C |
| - | */ | + | </WRAP> |
| - | The DMC60C is an electronic speed controller designed for driving | + | The DMC60C is the feature-packed, |
| {{Digilent Image Gallery | {{Digilent Image Gallery | ||
| Line 14: | Line 14: | ||
| | image = {{ : | | image = {{ : | ||
| }} | }} | ||
| + | |||
| + | ---- | ||
| + | ====== Features ====== | ||
| + | |||
| + | {{ : | ||
| + | |||
| + | ^ Callout | ||
| + | ^ 1 | Input Ground (GND) ^ 5 | Brake/Coast CAL Button | ||
| + | ^ 2 | Positive Input (V+) ^ 6 | Positive Output (M+) | | ||
| + | ^ 3 | Input Signal Cables (x2) ^ 7 | Output Ground (M-) | | ||
| + | ^ 4 | Status LEDs (x4) | || | ||
| ---- | ---- | ||
| Line 33: | Line 44: | ||
| ---- | ---- | ||
| ===== 2 Mechanical ===== | ===== 2 Mechanical ===== | ||
| - | |||
| - | FIXME: Add Diagrams | ||
| The DMC60C’s aluminum case is electrically isolated and may be mounted directly to a robot using zip-ties or #8-32 screws. The case may become hot after pro-longed use in high current applications. For optimum performance it is recommended that the DMC60C be mounted in a location that allows airflow over the top of the case and around both sides of the case. | The DMC60C’s aluminum case is electrically isolated and may be mounted directly to a robot using zip-ties or #8-32 screws. The case may become hot after pro-longed use in high current applications. For optimum performance it is recommended that the DMC60C be mounted in a location that allows airflow over the top of the case and around both sides of the case. | ||
| - | ---- | + | {{ :dmc-60c: |
| - | ====== Features ====== | + | |
| - | FIXME Add feature list | + | ^ Callout |
| + | ^ 1 | Zip Tie Grooves | ||
| + | ^ 2 | Mounting Holes and #8 Bolt/Nut Pocket Clearance | ||
| - | {{ : | + | ^ Mechanical Specifications Table || |
| - | + | ^ PARAMETER | |
| - | ^ Callout | + | | DMC60C Length |
| - | ^ 1 | + | | DMC60C Width |
| - | ^ 2 | + | | DMC60C Height |
| - | ^ 3 | + | | Mounting Hole Spacing |
| - | ^ 4 | + | |
| ---- | ---- | ||
| Line 69: | Line 78: | ||
| ---- | ---- | ||
| - | ===== 3 PWM Input Connections ===== | + | ===== 3 Input Signal Cable Connections ===== |
| - | The DMC60C | + | The DMC60C |
| - | The DMC60C' | + | The DMC60C continually measures the positive pulse width of the PWM Input Signal applied to the Input Signal Cable and maps it to an output voltage, or duty cycle. By default, a positive pulse width of 1.0 milliseconds corresponds to 100% duty cycle in the reverse direction (current flow from M- to M+), a positive pulse width of 2.0 milliseconds corresponds to 100% duty cycle in the forward direction (current flow from M+ to M-), and a positive pulse width of 1.5 milliseconds (+/- 4%) corresponds to neutral. When a neutral pulse width is detected, the present Brake/Coast setting is applied to the output. The DMC60C expects the PWM Input Signal to have an input period between 2.9 and 100 milliseconds. The allows te update rate to be as high as 344 Hz or as low as 10 Hz. |
| + | |||
| + | The DMC60C' | ||
| ---- | ---- | ||
| + | ===== 4 Motor Controller LEDs ===== | ||
| + | |||
| + | {{ : | ||
| + | //Figure 4.1 DMC60C LED Label Callout// | ||
| + | |||
| + | The DMC60C contains four RGB (Red, Green, and Blue) LEDs and one Brake/Coast CAL LED. The four RGB LEDs are located in the corners and are used to indicate status during normal operation, as well as when a fault occurs. The Brake/Coast CAL LED is located in the center of the triangle, which is located at the center of the housing, and is used to indicate the current Brake/Coast setting. When the center LED is off, the device is operating in coast mode. When the center LED is illuminated, | ||
| + | |||
| + | At power-on, the RGB LEDs illuminate Blue, continually getting brighter. This lasts for approximately five seconds. During this time, the motor controller will not respond to an input signal, nor will the output drivers be enabled. After the initial power-on has completed, the device begins normal operation and what gets displayed on the RGB LEDs is a function of the input signal being applied, as well as the current fault state. Assuming that no faults have occurred, the RGB LEDs function as follows: | ||
| + | |||
| + | ^ Table 4.1 LED Patterns in PWM Operating Mode || | ||
| + | ^ Servo Input Signal Applied | ||
| + | | No Input Signal or Invalid Input Pulse Width | Alternate between top (LED1 and LED2) and bottom (LED3 and LED4) LEDs being illuminated Red and Off. | | ||
| + | | Neutral Input Pulse Width | All 4 LEDs illuminated Orange. | ||
| + | | Positive Input Pulse Width | LEDs blink Green in a clockwise circular pattern (LED1 -> LED2 -> LED3 -> LED4 -> LED1). The LED update rate is proportional to the duty cycle of the output and increases with increased duty cycle. At 100% duty cycle, all 4 LEDs are illuminated Green. | ||
| + | | Negative Input Pulse Width | LEDs blink Red in a counter-clockwise circular pattern (LED1 -> LED4 -> LED3 -> LED2 -> LED1). The LED update rate is proportional to the duty cycle of the output and increases with increased duty cycle. At 100% duty cycle, all 4 LEDs are illuminated Red. | | ||
| + | |||
| + | ^ Table 4.2 LED Patterns in CAN Operating Mode || | ||
| + | ^ CAN Bus Control State ^ LED State | | ||
| + | | No Input Signal or CAN bus error detected | ||
| + | | No CAN Control Frame received within the last 100ms or the last control frame specified modeNoDrive (Output Disabled) | ||
| + | | Valid CAN Control Frame received within the last 100ms. The specified control mode resulted in a Neutral Duty Cycle being applied to Motor Output | ||
| + | | Valid CAN Control Frame received within the last 100ms. The specified control mode resulted in a Positive Duty Cycle being Motor Output | ||
| + | | Valid CAN Control Frame received within the last 100ms. The specified control mode resulted in a Negative Duty Cycle being Motor Output | ||
| + | |||
| + | ---- | ||
| + | ===== 5 Brake / Coast Mode ===== | ||
| + | |||
| + | The DMC60C' | ||
| + | |||
| + | The current Brake/Coast setting is displayed by the Brake/Coast CAL LED, which is in the center of the triangle located at the center of the housing. When the device is operating in Brake Mode, the LED is illuminated Red. When the device is operating in Coast Mode, the LED is off. The Brake/Coast setting can be toggled by pressing down on the center of the triangle, then releasing the button. | ||
| + | |||
| + | The Brake/Coast setting is stored in non-volatile memory and is re-stored automatically after power cycles. | ||
| + | |||
| + | When the DMC60C is connected to a CAN bus the Brake/Coast setting may be overridden by the CAN control frame. When the Brake/Coast override is active the Brake/Coast CAL LED is overridden to display the setting specified by the CAN control frame. During this time the DMC60C employs the Brake/Coast mode that is specified in the CAN frame when applying the neutral duty cycle to the output. | ||
| + | |||
| + | ---- | ||
| + | ===== 6 Input Signal Calibration ===== | ||
| + | |||
| + | The DMC60C accepts PWM input signals with a positive pulse width between 0.6 and 2.4 milliseconds. Due to variations in controllers, | ||
| + | |||
| + | To perform calibration, | ||
| + | * 1. Press and hold the Brake/Coast CAL button. After approximately 5 seconds, the top and bottom LEDs will begin to alternate between Blue and Off. This indicates that calibration has started. | ||
| + | * 2. While continuing to hold the button, use the controller to move between full forward and full reverse (perhaps by moving a joystick), making sure to reach both extremes. This may be repeated more than once, but there is no required minimum. | ||
| + | * 3. Return the controller to neutral (return the joystick to the neutral position). | ||
| + | * 4. Release the Brake/Coast CAL button. | ||
| + | * 5. If calibration was successful, then the top and bottom LEDs will quickly alternate between Green and Off and the new calibration constants will be stored in non-volatile memory. If calibration failed, then the top and bottom LEDs will quickly alternate between Red and Off and the device will continue to operate using the existing calibration constants. | ||
| + | |||
| + | **Note:** // | ||
| + | |||
| + | To restore default calibration: | ||
| + | * 1. Disconnect the power source from the DMC60C. | ||
| + | * 2. Hold the Brake/Coast CAL button down. | ||
| + | * 3. While continuing to hold the button, apply power to the DMC60C. | ||
| + | * 4. Continue holding down the button until the top and bottom LEDs alternate quickly between Green and Off. | ||
| + | * 5. Release the Brake/Coast CAL button. | ||
| + | |||
| + | **Note:** //This will also restore all DMC60C settings to their factory default state.// | ||
| + | |||
| + | ---- | ||
| + | ===== 7 Internal Temperature Monitoring and Over Temperature Protection ===== | ||
| + | |||
| + | The DMC60C features an onboard thermistor, which allows the temperature of the circuit board to be continuously monitored. When the motor controller detects that the temperature of the circuit board has exceeded 70°C it will begin to decrease the duty cycle of the output. Additionally, | ||
| + | |||
| + | ---- | ||
| + | ===== 8 Input Voltage Monitoring and Under Voltage Protection ===== | ||
| + | |||
| + | The DMC60C continuously monitors the input voltage. If the input voltage falls below 5.75 Volts (+/- 2%) for 5 or more seconds, then the output duty cycle will be set to 0% and an under voltage fault is signaled. The output will remain disabled until the fault is cleared (3 seconds), at which point it may be re-enabled if the under-voltage condition is no longer present. | ||
| + | |||
| + | ---- | ||
| + | ===== 9 Fault Indicators ===== | ||
| + | |||
| + | When a fault condition is detected, the output duty cycle is reduced to 0% and a fault is signaled. The output then remains disabled for 3 seconds. During this time the onboard LEDs (LED1-4) are used to indicate the fault condition. The fault condition is indicated by toggling between the top (LED1 and LED2) and bottom (LED3 and LED4) LEDs being illuminated Red and off. The color of the bottom LEDs depends on which faults are presently active. The table below describes how the color of the bottom LEDs maps to the presently active faults. | ||
| + | |||
| + | ^ Table 9.1 Fault Indicator LED Colors | ||
| + | ^ Color | Over Temperature | ||
| + | | Green | Present | ||
| + | | Blue | Not Present | ||
| + | | Cyan / Aqua | Present | ||
| + | |||
| + | ---- | ||
| + | ===== 10 Expansion Connector ===== | ||
| + | |||
| + | The DMC60C includes a 10-pin (2 x 5, 0.050” pitch) expansion port that allows sensors to be directly attached to the controller. Presently it supports direct attachment of limit switches and quadrature encoders. The figure below shows the pinout. Please note that any sensor attached to the expansion port should be powered through pin 1 (+3.3V) and/or pin 2 (+5V) and should not be powered by an external voltage supply. | ||
| + | |||
| + | {{ : | ||
| + | //Figure 10.1 DMC60C Expansion Port Pinout// | ||
| + | |||
| + | ==== 10.1 Expansion Port Electrical Specifications ==== | ||
| + | |||
| + | ^ Table 10.1.1 Expansion Port Electrical Specifications | ||
| + | ^ PARAMETER | ||
| + | ^ +3.3V Supply Voltage | ||
| + | ^ +3.3V Supply Current | ||
| + | ^ +5V Supply Voltage | ||
| + | ^ +5V Supply Current | ||
| + | ^ Digital Input Signal Logic High Threshold[(All expansion port digital input pins tolerate input voltages up to 5.5V. Each of these pins is clamped to the 3.3V supply through a 200 ohm resistor and a Schottky diode)] (Encoder A, B, Index, Fwd/Rev Limit) | ||
| + | ^ Digital Input Signal Logic Low Threshold (Encoder A, B, Index, Fwd/Rev Limit) | ||
| + | |||
| + | ~~REFNOTES~~ | ||
| + | ---- | ||
| + | ===== 11 Limit Switches ===== | ||
| + | |||
| + | The DMC60C expansion port includes pins for attaching both forward and reverse limit switches. These input pins can be individually configured to interface with a normally open or normally closed switch using Digilent’s web-based configuration utility on the RoboRio or by sending the appropriate CAN frame on the CAN bus. Additionally, | ||
| + | |||
| + | By default, both the forward and reverse limit switch inputs are enabled and configured to interface with normally open switches. When a limit switch is active the DMC60C will not allow the motor output to be driven in the associated direction. Any attempt to drive the output in the direction of an active limit switch will result in the neutral duty cycle being applied to the H-Bridge. | ||
| + | |||
| + | The onboard Microcontroller uses internal pull-ups on both pins, and as a result, no external pull-ups are required. The diagrams that follow show how to wire switches to the forward and reverse limit switch inputs. | ||
| + | |||
| + | {{ : | ||
| + | //Figure 11.1// | ||
| + | |||
| + | {{ : | ||
| + | //Figure 11.2// | ||
| + | |||
| + | {{ : | ||
| + | //Figure 11.3// | ||
| + | |||
| + | {{ : | ||
| + | //Figure 11.4// | ||
| + | |||
| + | ---- | ||
| + | ===== 12 Quadrature Encoder Input ===== | ||
| + | |||
| + | The DMC60C can perform closed loop velocity and closed loop position control. Velocity and position measurements are made using a quadrature encoder. A quadrature encoder may be attached to the Encoder A, Encoder B, and Encoder Index (optional) pins of the DMC60C expansion port. Please note that the encoder should be powered by the +3.3V or +5V pins of the expansion port, and that these pins should **never** be connected to each other. | ||
| + | |||
| + | {{ : | ||
| + | //Figure 12.1 DMC60C Quadrature Encoder Connection// | ||
| + | |||
| + | ^ Table 12.1 Quadrature Encoder Input Specifications | ||
| + | ^ PARAMETER | ||
| + | | Quadrature Encoder Counts per Revolution | ||
| + | | Quadrature Encoder RPM | 78,643,200 / Max Counts Per Revolution | ||
| + | |||
| + | ---- | ||
| + | ===== 13 Quadrature Encoder Index ===== | ||
| + | |||
| + | The DMC60C expansion port includes a pin (Encoder Index) for attaching a digital sensor or a switch to automatically clear the quadrature encoder’s position count. The onboard Microcontroller uses an internal pull-up, which makes it possible to attach a switch directly without the need for an external pull-up. | ||
| + | |||
| + | The DMC60C can be configured to clear the position count in response to a rising or falling (default) edge on the Encoder Index pin. By default, this functionality is disabled, and any input applied to the Encoder Index pin is ignored by the DMC60C. | ||
| + | |||
| + | The DMC60C may also be configured to clear the position count based on the logic level of a signal applied to the Forward Limit or Reverse Limit pins of the expansion connector. By default, this functionality is disabled. The active state required to clear the position count is dependent on the configuration of the associated limit switch input. For example, if the Forward Limit switch is configured as a normally open switch then a logic ‘0’ on the Forward Limit pin will cause the position count to be cleared when this functionality is enabled. If the Forward Limit switch is configured as a normally closed switch, then a logic ‘1’ on the Forward Limit pin causes the position count to be cleared when this functionality enabled. Please note that the position count continues to be cleared for as long as the associated pin remains driven to the active state. | ||
| + | |||
| + | The figures below show how to attach a switch to the Encoder Index pin of the expansion port. | ||
| + | |||
| + | {{ : | ||
| + | //Figure 13.1// | ||
| + | |||
| + | {{ : | ||
| + | //Figure 13.2// | ||
| + | |||
| + | ---- | ||
| + | ===== 14 Restoring Factory Default Connections ===== | ||
| + | |||
| + | Perform the following steps to restore factory default settings: | ||
| + | * 1. Disconnect the power source from the DMC60C. | ||
| + | * 2. Hold the Brake / CAL button down. | ||
| + | * 3. While continuing to hold the button, apply power to the DMC60C. | ||
| + | * 4. Continue holding down the button until the top and bottom LEDs alternate quickly between Green and Off. | ||
| + | * 5. Release the Brake / CAL button. | ||
| - | FIXME Add Button | + | The manufacture date string, hardware revision number string, |
| ---- | ---- | ||
| {{tag> | {{tag> | ||