Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
daq-and-datalogging:documents:using-mcc-daq-digital-io [2023/06/14 06:46] – Scandiwebdaq-and-datalogging:documents:using-mcc-daq-digital-io [2023/07/27 21:28] (current) – Arthur Brown
Line 1: Line 1:
-====== TechTip: ====== +====== TechTip: Utilizing Digital Inputs / Outputs with MCC DAQ ======
- +
-===== Utilizing Digital Inputs / Outputs with MCC DAQ =====+
  
 **Objective**\\  **Objective**\\ 
Line 58: Line 56:
 The following example shows how to control a digital output bit using LabVIEW. The wiring diagram below shows the pertinent VIs and settings. Here just the first bit (Do0) of the Auxport on hardware device #0 is configured for output, and then it is tasked with outputting the true/false value the operator enters\\  The following example shows how to control a digital output bit using LabVIEW. The wiring diagram below shows the pertinent VIs and settings. Here just the first bit (Do0) of the Auxport on hardware device #0 is configured for output, and then it is tasked with outputting the true/false value the operator enters\\ 
  
-{{https://files.digilent.com/resources/measurement-computing/Reference Images/TT-DIO-ULx-wiring-diagram.png?625x152}}\\ +{{https://files.digilent.com/reference-images/TT-DIO-ULx-wiring-diagram.png?625x152}}\\ 
  
 DASYLab\\  DASYLab\\ 
Line 64: Line 62:
  
  
-{{https://files.digilent.com/resources/measurement-computing/Reference Images/TT-DASYLab-DO.png?342x231}}\\ +{{https://files.digilent.com/reference-images/TT-DASYLab-DO.png?342x231}}\\ 
  
 Double clicking on the Switch module allows you to access a menu where you can specify how often the switch position will be monitored. Below we see that 1 Hz is selected, resulting in digital output bit D0 on the DAQ hardware being updated every second to match the operator’s selection.\\  Double clicking on the Switch module allows you to access a menu where you can specify how often the switch position will be monitored. Below we see that 1 Hz is selected, resulting in digital output bit D0 on the DAQ hardware being updated every second to match the operator’s selection.\\ 
  
-{{https://files.digilent.com/resources/measurement-computing/Reference Images/TT-DASYLab-DO-timebase.png?379x225}}\\  +{{https://files.digilent.com/reference-images/TT-DASYLab-DO-timebase.png?379x225}}\\ 
- +
-More Information\\  +
-Please contact Measurement Computing Corporation if you have any questions or if you would like any further information.\\ +
  
-Knowledgebase: [[https://kb.mccdaq.com/Default.aspx | kb.mccdaq.com]]\\  +**More Information**\\  
-Phone: 508-946-5100\\  +Please reach out to our support team on the Digilent Forum if you have any questions: [[https://forum.digilent.com/]]
-Fax: 508-946-9500\\ +
      
-Additional TechTips are available on our [[https://www.mccdaq.com/Technical-Articles | Data Acquisition Technical Articles web page.]]+Additional TechTips are available here in Digilent Reference: [[start]]