| - | ====== TechTip: ====== | + | ====== TechTip: |
| - | ===== How to Measure Thermocouples using a DAQ Device ===== | + | **What is a Thermocouple? |
| - | **What is a thermocouple? | ||
| Thermocouples are a popular and inexpensive way to measure temperature. The thermocouple is a simple device – two wires of different metals welded together at one end. But this " | Thermocouples are a popular and inexpensive way to measure temperature. The thermocouple is a simple device – two wires of different metals welded together at one end. But this " | ||
| Line 9: | Line 8: | ||
| {{https:// | {{https:// | ||
| - | **Figure 1: Type T Basic Thermocouple Circuit.** A classic thermocouple measurement system requires two sensors: one for the environment being measured and the other for a reference junction, normally held to 0 °C (32 °F). | + | **Figure 1: Type T Basic Thermocouple Circuit.** |
| + | |||
| + | A classic thermocouple measurement system requires two sensors: one for the environment being measured and the other for a reference junction, normally held to 0 °C (32 °F). | ||
| One junction is normally held at a constant reference temperature while the opposite junction is immersed in the environment to be measured. The principle of operation depends on the unique value of thermal electromotive force (EMF) measured between the open ends of the leads and the junction of two dissimilar metals held at a specific temperature. | One junction is normally held at a constant reference temperature while the opposite junction is immersed in the environment to be measured. The principle of operation depends on the unique value of thermal electromotive force (EMF) measured between the open ends of the leads and the junction of two dissimilar metals held at a specific temperature. | ||
| Line 17: | Line 18: | ||
| The voltage difference that develops at the open end of the thermocouple is quite small in the uV range. This voltage cannot be accurately measured using a typical multifunction DAQ device with for example a 0-10 V range. This small signal requires gains in the range of x100, which is not typically provided on traditional multifunction DAQ devices. And, because thermocouples generate a relatively small voltage, noise is always an issue. The most common sources of noise are the AC power lines (50 Hz or 60 Hz). Because the bandwidth of most temperature systems is lower than 50 Hz, a simple filter in each channel can reduce the interfering AC line noise. Common filters include passive filters, using only resistors and capacitors, and active filters using these components along with op amps. While a passive RC filter is inexpensive and works well for analog circuits, it's not recommended for a multiplexed front end because the multiplexer load can change the filter characteristics. An active filter composed of an op amp and a few passive components works well in multiplexed systems, but it's more expensive and complex. | The voltage difference that develops at the open end of the thermocouple is quite small in the uV range. This voltage cannot be accurately measured using a typical multifunction DAQ device with for example a 0-10 V range. This small signal requires gains in the range of x100, which is not typically provided on traditional multifunction DAQ devices. And, because thermocouples generate a relatively small voltage, noise is always an issue. The most common sources of noise are the AC power lines (50 Hz or 60 Hz). Because the bandwidth of most temperature systems is lower than 50 Hz, a simple filter in each channel can reduce the interfering AC line noise. Common filters include passive filters, using only resistors and capacitors, and active filters using these components along with op amps. While a passive RC filter is inexpensive and works well for analog circuits, it's not recommended for a multiplexed front end because the multiplexer load can change the filter characteristics. An active filter composed of an op amp and a few passive components works well in multiplexed systems, but it's more expensive and complex. | ||
| - | Cold Junction Compensation | + | **Cold Junction Compensation** |
| Ice baths and multiple-reference junctions in large test fixtures can be difficult to set up and maintain, but fortunately they all can be eliminated. The EMF correction needed at the terminals can be referenced and compensated to the NIST standards through computer software. When the ice baths are eliminated, cold-junction compensation is still necessary to obtain accurate thermocouple measurements. The software has to read the isothermal block temperature. One widely used technique is a thermistor mounted close to the isothermal terminal block and connected to the external thermocouple leads. No temperature gradients are allowed in the region containing the thermistor and terminals. The type of thermocouple used is preprogrammed for its respective channel, and the dynamic input data for the software includes the isothermal block temperature and the measured environmental temperature. The software uses the isothermal block temperature and the type of thermocouple to calculate the temperature of the sensor using a polynomial equation. The method allows many thermocouple channels of various types to be connected simultaneously while the computer automatically handles all of the conversions. | Ice baths and multiple-reference junctions in large test fixtures can be difficult to set up and maintain, but fortunately they all can be eliminated. The EMF correction needed at the terminals can be referenced and compensated to the NIST standards through computer software. When the ice baths are eliminated, cold-junction compensation is still necessary to obtain accurate thermocouple measurements. The software has to read the isothermal block temperature. One widely used technique is a thermistor mounted close to the isothermal terminal block and connected to the external thermocouple leads. No temperature gradients are allowed in the region containing the thermistor and terminals. The type of thermocouple used is preprogrammed for its respective channel, and the dynamic input data for the software includes the isothermal block temperature and the measured environmental temperature. The software uses the isothermal block temperature and the type of thermocouple to calculate the temperature of the sensor using a polynomial equation. The method allows many thermocouple channels of various types to be connected simultaneously while the computer automatically handles all of the conversions. | ||
| - | Open Thermocouple Detection | + | **Open Thermocouple Detection** |
| Detecting open thermocouples easily and quickly is especially critical in systems with many channels. Thermocouples tend to break or increase resistance when exposed to vibration, poor handling, and long service time. A simple open-thermocouple detection circuit consists of a small capacitor placed across the thermocouple leads and driven with a low-level current. The low impedance of the intact thermocouple presents a virtual short circuit to the capacitor, so it cannot charge. When a thermocouple opens or significantly changes resistance, the capacitor charges and drives the input to one of the voltage rails, which indicates a defective thermocouple (See Figure 2). | Detecting open thermocouples easily and quickly is especially critical in systems with many channels. Thermocouples tend to break or increase resistance when exposed to vibration, poor handling, and long service time. A simple open-thermocouple detection circuit consists of a small capacitor placed across the thermocouple leads and driven with a low-level current. The low impedance of the intact thermocouple presents a virtual short circuit to the capacitor, so it cannot charge. When a thermocouple opens or significantly changes resistance, the capacitor charges and drives the input to one of the voltage rails, which indicates a defective thermocouple (See Figure 2). | ||
| {{https:// | {{https:// | ||
| - | **Figure 2: Open Thermocouple Detector.** | + | **Figure 2: Open Thermocouple Detector.** |
| - | Thermocouple Measurement Devices | + | The thermocouple |
| - | DAQ devices that are not specifically designed for thermocouple | + | |
| - | More Information\\ | + | **Thermocouple |
| - | Please contact | + | |
| + | DAQ devices that are not specifically designed for thermocouple measurements lack the needed signal conditioning and CJC required to accurately measure thermocouples. Devices | ||
| - | Knowledgebase: | + | **More Information** |
| - | Phone: 508-946-5100\\ | + | |
| - | Fax: 508-946-9500\\ | + | |
| - | Additional TechTips are available on our [[https:// | + | |
| + | Please reach out to our support team on the Digilent Forum if you have any questions: [[https:// | ||
| + | | ||
| + | Additional TechTips are available here in Digilent Reference: [[start]] | ||