-====== TechTip: ====== +====== TechTip: Basic Analog Input Signal Connections (Part 2) ======
- +
-===== Basic Analog Input Signal Connections (Part 2) =====+
  
 **Objective**\\  **Objective**\\ 
Line 31: Line 29:
 MCC recommends using a single-ended configuration for the common ground scenario. However, if only some input channels/channel pairs are common ground, we recommend using the differential mode for all inputs. Figure 1 shows the recommended connections for a common ground/single-ended input system. MCC recommends using a single-ended configuration for the common ground scenario. However, if only some input channels/channel pairs are common ground, we recommend using the differential mode for all inputs. Figure 1 shows the recommended connections for a common ground/single-ended input system.
  
-{{https://files.digilent.com/resources/measurement-computing/Reference Images/SigSourceCommGndSE.png?632x283}}\\ +{{https://files.digilent.com/reference-images/SigSourceCommGndSE.png?632x283}}\\ 
  
 **Figure 1.** Signal source and AI DAQ device sharing common ground connected to single-ended input\\  **Figure 1.** Signal source and AI DAQ device sharing common ground connected to single-ended input\\ 
  
-{{https://files.digilent.com/resources/measurement-computing/Reference Images/picture 12.png?690x243}}\\ +{{https://files.digilent.com/reference-images/picture 12.png?690x243}}\\ 
  
 **Common Ground / Differential Inputs**\\  **Common Ground / Differential Inputs**\\ 
 Using a differential configuration is acceptable for common ground connections, although it requires more wiring and offers fewer channels than a single-ended configuration (see Figure 2). Using a differential configuration is acceptable for common ground connections, although it requires more wiring and offers fewer channels than a single-ended configuration (see Figure 2).
  
-{{https://files.digilent.com/resources/measurement-computing/Reference Images/SigSourceCommGndDiff.png?695x267}}\\ +{{https://files.digilent.com/reference-images/SigSourceCommGndDiff.png?695x267}}\\ 
  
 **Figure 2.** Signal source and AI DAQ device sharing common ground connected to differential input\\  **Figure 2.** Signal source and AI DAQ device sharing common ground connected to differential input\\ 
Line 75: Line 73:
 For the best performance with isolated signal sources, MCC recommends using a differential input configuration. Figure 7 shows the recommended connections for this configuration.\\  For the best performance with isolated signal sources, MCC recommends using a differential input configuration. Figure 7 shows the recommended connections for this configuration.\\ 
  
-{{https://files.digilent.com/resources/measurement-computing/Reference Images/SE-Iso.png?708x310}}\\ +{{https://files.digilent.com/reference-images/SE-Iso.png?708x310}}\\ 
  
 **Figure 7.** Isolated signal source connected to differential input\\  **Figure 7.** Isolated signal source connected to differential input\\ 
  
 +**More Information**\\ 
 +Please reach out to our support team on the Digilent Forum if you have any questions: [[https://forum.digilent.com/]]
 +  
 +Additional TechTips are available here in Digilent Reference: [[start]]
  